The calibration function is also
available through the Industrial
Ethernet interface (see
The acceptable minimum and
maximum pressure limits can be set
as desired within the stated range
according to the following (see
):
1. Click the
Settings
menu in the
upper left corner of the Main
screen and hover over
Pressure
Limits
. Click on the desired limit
to set.
2. Enter a desired lower or upper
limit within the stated range
using the provided value field.
The purge pressure limits
are in mbar relative to the
calibrated ambient
pressure.
3. Click
OK
to apply the settings.
Figure 37
Pressure readings outside the
acceptable range result in a fault
condition.
To Disable or Suppress the
Low Purge Fault
To disable faults generated
by a purge pressure reading
below the lower limit
permanently, set the lower
limit to zero.
To suppress the lower limit
temporarily, click on the
Suppress Low Purge Fault
or set the corresponding
Industrial Ethernet bit. See