PLMNL0232 REV. H Effective Date: 01/14/19
33
FiberCUT
®
2D Operation Manual
Figure 38
A checkmark appears if a fault
is currently suppressed.
Clicking the checkmark will
restore the fault.
The fault is automatically
restored following a power cycle
of the controller.
4.4.5 Temperature Limits
The acceptable upper temperature
limit can be set as desired within the
stated range for the following
components:
Electronics
Upper Cover Glass
Collimator
Process Monitor
Focusing Lens
Lower Cover Glass
Nozzle
Temperature readings outside the
acceptable range will result in a
fault condition.
To modify the desired upper
temperature limit:
1. Click the
Settings
menu in the
upper left corner of the Main
screen and hover over
Temperature Limits
. Click on the
desired temperature range to
set. See
Figure 39
appear.
Figure 40
2. Enter a desired upper limit that
is within stated range using the
provided value field.
3. Click
OK
to apply the settings.