19. EMERGENCY CONTROL PANEL
It comes complete with its plasterboard recessed box. The control
panel acts as a receiver for the remote control and must be operated
manually only for emergency operation in the event of breakdown or
loss of the remote control.
WARNING: it should be positioned so that it is
visible and accessible and not near heat sources. It may
also not be visible on the external plasterboard as it
communicates via radio with the remote control.
20. POSITIONNEMENT DU BRASIER
It is forbidden to use the device without a brazier. The brazier must be
correctly positioned in its seat and pushed towards the rear wall of the
combustion chamber.
21. POWER ON AND USE
FIRST USE, START-UP WITH NEW APPLIANCE
When using your new appliance for the first time (or when the pellet
tank is completely empty), remember that the loading auger is empty
and therefore, before turning on the appliance, you must comply with
the following procedure with the fireplace off:
Check that the electrical outlet is plugged in and that there is
power.
Check that the batteries are in the remote control and that it works.
Check that you have set the time and date setting in the radio
control menu.
Fill the tank with pellets and check that the loading door is
completely closed.
Run MENU 08 INITIAL LOAD: on the remote control (see
dedicated instruction booklet).
At the end of this initial loading cycle, completely empty the brazier
of fallen pellets so that it is perfectly clean.
Respect all the indications in the following paragraph “STANDARD
START-UP”.
At the first POWER ON, unpleasant odors can be
released in the room due to the presence of grease on
the components and the normal "thermal break-in"
process. Ventilate the room well and do not stay there
until the odors have stopped, using the appliance at
maximum power.
The paint used is water-based, totally free of volatile toxic materials,
to give you a product that respects nature and is always of high
quality.
STANDARD IGNITION
IMPORTANT. Before switching on your appliance,
you must comply with the following procedure (with the
appliance off) and the following warnings; non-
compliance determines the termination of the warranty
and the attached liability of the manufacturer:
1.
FILL THE PELLET TANK OR MAKE SURE IT CONTAINS SUCH
A QUANTITY OF FUEL THAT THE APPLIANCE WORKS FOR
THE DESIRED PERIOD.
2.
VERIFY THAT THE FILLING DOOR OF THE TANK IS
COMPLETELY CLOSED.
3.
CARRY OUT THE DAILY CLEANING OF THE BRAZIER,
GLASS AND THE ENTIRE COMBUSTION CHAMBER (SEE
MAINTENANCE AND CLEANING CHAPTER): THE BRAZIER
MUST BE STRICTLY EMPTY AND ITS HOLES CLEAN.
4.
VERIFY THAT THE BURN POT IS CORRECTLY POSITIONED:
PUSHED TOWARDS THE REAR WALL OF THE COMBUSTION
CHAMBER.
5.
CHECK THAT THE APPLIANCE DOOR IS PERFECTLY
CLOSED.
6.
IN
CASE
OF
PROGRAMMED
IGNITIONS
WITH
CHRONOTHERMOSTAT, USING THE STAND-BY FUNCTION
OR REMOTELY VIA THE APP, AFTER THE LAST
SHUTDOWN, MAKE SURE THAT ALL THE CONDITIONS
REFERRED TO IN POINTS 1-2-3-4-5 ARE RESPECTED.
7.
Carry out normal ignition via radio control: for the correct use of
the remote control and all its functions, follow the dedicated
instruction manual (code 40297) supplied with the appliance.
8.
If during the ignition phase this does not happen and you notice a
lot of smoke in the combustion chamber, immediately switch off
the appliance and replace the pellet in your possession, this
could be of poor quality and / or have too high humidity. .
Insisting on switching on could make your appliance dangerous:
if this persists, contact the Service Center to make additional
adjustments and optimize use.
WARNINGS: It is absolutely FORBIDDEN to use
flammable liquid substances for lighting (such as
alcohol, petrol, petroleum and the like).
NO IGNITION
It may happen that if the ignition is not detected (flame inside the
brazier) within a certain time, the ignition failure alarm is activated.
The message “AL 5 NO IGNITION” appears on the radio control
display and an acoustic signal is emitted at regular intervals (if the
buzzer function of Menu 07 is active). To deactivate the alarm status,
long press (about 3 seconds) the ON-OFF button: the acoustic alarm
stops and the device returns to the first "FINAL CLEANING" and then
"OFF" status.