STARFIRE:
air fireplaces with vertical glass
(1) AIR ENTRY IN THE COATING
: it is obligatory to always ensure a
minimum ventilation inlet and outlet in the coating through a grid at the
bottom and a grid above (decompression) of
at least 450 cm2 each
.
They can be done frontally, laterally or even later, provided that the
circle of air entering and leaving is always inside the house (and not
outside).
(2) INSPECTION DOOR:
to load the
pellets into the tank, periodic maintenance
as well as annual cleaning of the chimney
flue, spare parts, it is mandatory to leave
the electronic components on the side (as
standard to right, looking at the chimney
from the front) a sufficient inspection door
to access all the components (pellet load,
control unit, fume extractor, air fans, glow
plug) of
at least 50x140 cm in height
.
Check whether it is sufficient for access to
the upper telescopic tube connected to
the flue connection and to grip and slam
the internal turbulator for seasonal cleaning.
In addition, on the left side (facing the
chimney face), it is mandatory to carry a
door
at least 30x25 cm (we recommend
making a removable grille for air inlet).
to clean the flue integrated in the device
(we recommend making a removable
grille for air inlet).
This inspection door can be avoided if on
the right side there is a larger inspection
door, at
least 50 x 160 cm high, which
must start from the ground
and allow to reach the rear inspection
cap on the T, to access the upper telescopic tube connected to the
flue connection and to hold and beat the internal turbulator for
seasonal cleaning.
(3) FRONT OUTPUT OF THE HOT AIR FAN:
The appliance is supplied with a 250 m3 / h rear tangential fan that
pushes the hot air towards the 2 upper collars of Ø 80:
it is possible
to channel the air at the top up to a maximum distance of 1.5
meters.
If you want to let the air out front and not above, you can remove the
upper collars and the front plate and plug the two upper holes with the
appropriate plate provided. In this case, provide a front grill of
at least
33x4 cm
in the covering at the air outlet.
(4) TOP HOT AIR FAN LINE:
The unit is supplied with two top fans to
heat room air:
• A 180 m3 / h right upper centrifugal fan with a hot air outlet of Ø 60
mm that can be traveled up to a maximum distance of 5 meters,
manageable by the remote client (VENT-3) from the speed 0) to 5
(max) or automatic.
• Upper left centrifugal fan 180 m3 / h with hot air outlet Ø 60 mm that
can be traversed up to a maximum distance of 5 meters, manageable
by the remote client (VENT-2) from speed 0) to 5 (max) or automatic.
For optimal installation, we recommend using thermally and
acoustically insulated pipes to ensure the best acoustic and thermal
comfort.
Warning: using the appliance at powers 3 - 4 - 5, the ducted fans
will automatically start at speed 3 and cannot be switched off
(even if set to 0) to prevent the appliance from overheating.
SUPERIOR DEFLECTORS
The vertical models have 2 inclined deflectors to be positioned
interlocking as shown in the following diagram: