L’ARTISTICO SRL |
EN
40
Cod. 40115 | Rev. 19 | 05/2021
MONTHLY CLEANING
1) CLEANING THE TANK
: The pellet hopper should be
emptied and cleaned once a month. Sawdust residue can form
plugs in the auger and block the loading system.
2) CLEANING THE DEFLECTOR
: depending on the
appliance, the deflector (s) (if any) positioned to rest in the upper
part of the combustion chamber, must be removed and cleaned
regularly, letting all the soot accumulated on them fall. Then
reposition them in the appropriate place.
3)
REAR SMOKE CLEANING
: remove the brazier, remove
the upper deflectors and, depending on the model, lift the 3
interlocking vermiculite stops (in models with front glass) or
unscrew the vermiculite stop rod (in models with corner glass or 3
glasses). Finally, slide and remove the vermiculite side panels,
then the back panels. Using a vacuum cleaner, carefully clean the
heat exchanger compartment located behind the vermiculite panels
and clean the entire combustion chamber of accumulated granule
particles and ash. Put everything back.
WARNING: vermiculites are very fragile: handle with the
greatest care: their breakage is not covered by the warranty.
ANNUAL CLEANING
Combustion chamber
Smoke deflectors
Smoke deposit box
Helical turbulator inside the flue, when present
Seals
Connection pipe to the flue
Fans
Snorkel
Rear area and dust extraction on electronic components
Complete flue
ATTENTION: this annual cleaning operation of the
appliance is mandatory and must be carried out
exclusively by a qualified technician authorized by the
company, the smoke passes must be cleaned and the
state of all mechanical and electronic components must
be checked.
The qualified technician must issue you a "Inspection
and maintenance report" which is valid for the
appliance warranty and for your home insurance.
Flue cleaning:
Mechanical sweeping of the flue by a qualified technician is
mandatory for each heating season
or for the consumption of
1000kg of pellets (the situation that occurs first).
Always check that the appliance is in perfect working order and
especially that the gaskets are not worn, that the connections to
the flue are well made and watertight, that the mechanical parts
are not damaged.
Gaskets:
The gaskets guarantee the tightness of the appliance and the
consequent good functioning of the same. They must be checked
periodically: if they are worn or damaged, they must be replaced.
These operations must be carried out by an authorized technician.
Seals are considered wear items and are not covered by the warranty.
ATTENTION: check every 2 years if the buffer
battery of the electronic board needs to be replaced.
Decommissioning (end of season)
At the end of each season, before turning off the appliance, it is
advisable to completely empty the pellet tank, sucking up any residual
pellets and dust inside. We also invite you to disconnect the generator
from the mains and, for greater safety, especially in the presence of
children, remove the power cable
Fig. 46