background image

 

Larson Electronics LLC     www.LarsonElectronics.com     [email protected]

 

9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364  

 
There are four pre-drilled holes at the bottom of the pan-tilt. 

1.

 

Mark the centers of the four holes on the board according to the layout. 

2.

 

Drill four holes of appropriate diameters on the thin board. 

3.

 

Choose stainless steel metric bolts with suitable length and diameter (not provided) base on 
the thickness of the board or the wall. The pre-drilled hole is M6x1x80 for the 40W and 
M8x1x80 for the 80W. Stainless steel metric bolts are recommended. The chosen bolt should 
be slightly shorter than or equal to the thickness of wall +80mm. 

4.

 

Tighten the bolts onto the light through the drilled holes. 

CAUTION:

 Make sure the voltage of the power supply matches the input voltage of the light. 

Connecting a power source of wrong voltage to the light can damage the light permanently. Also make 
sure the chosen bolts are of proper length and specification. If bolts are too short, too long, or to small, 
the light may not be secured properly. 

Flat Surface with Easy Mount 

Easy Mount is only available for the 40W models. There are two installation options to use the Easy 
Mount (optional accessory). Four special lug bolts are shipped with an Easy Mount. 

Option 1:

 Mount Locking Base of Easy Mount Permanently on Flat Surface 

Typical application of this method is where the locking base of the standard Easy Mount is permanently 
mounted on a flat surface while the light can be attached or detached quickly for security and storage 
purpose. Tighten four stainless steel M6 screws of appropriate head size and length (not supplied) at 
the four outer holes on the locking base of the Easy Mount onto the flat surface. The locking base will 
be left in place on the flat surface permanently.   

Option 2:

 Attach Locking Base of Easy Mount Temporarily on a Flat Surface by Magnets 

Typical application of this method is where the flat surface is ferrous and suitable for magnetically 
attached heavy equipment securely. The light is securely tightened on the locking base of the Easy 
Mount with Magnets. There are four magnets permanently installed at the bottom of the locking base 
of the Easy Mount. Refer to below instructions for mounting the light onto Easy Mount. The whole 
assembly of the Easy Mount with the light securely mounted Is quickly attached to or detached from 
the flat surface. 

CAUTION: We do not recommend that the whole assembly is left on the surface while the underlying 
object moves. We cannot warrant the safety of this mounting method because we cannot predict the 
ferrous condition of the surface. This mounting method is used at customers own risk. Excessive speeds 
may cause the light to fly off of the moving object. Please consider mounting the locking base 
permanently as an alternative.  

Summary of Contents for RCL360-LED-40

Page 1: ...o remain steady regardless of battery discharging status For example a 24V 26AH rechargeable battery can power a 40W light continuously at regular intensity for up to 60 hours This light may also be powered directly by an optional 110 220 VAC to 12 24 VDC converter An optional adapter cable is available to connect these searchlights to cigarette lighter sockets of automobiles A specially coated te...

Page 2: ...to the normal functioning of the light when it is used in extreme high or low temperatures beyond that range The magnetic mount can withstand wind speed up to 60 mph We DO NOT recommend operating a magnetically mounted light on any object that may move at a high speed STROBE WARNING Exposure to strobe lights may cause dizziness disorientation and nausea A small percentage of people suffer from pho...

Page 3: ...ing a switch to the DC power source circuit to turn power to the light on off easily Securely connect the exposed RED wire from the pan tilt to the positive terminal of the connection cable from your DC power source Securely connect the exposed BLACK wire form the pan tilt to the negative terminal of the connection cable from your DC power source Insulate the connections to avoid any electrical sh...

Page 4: ...sy Mount Permanently on Flat Surface Typical application of this method is where the locking base of the standard Easy Mount is permanently mounted on a flat surface while the light can be attached or detached quickly for security and storage purpose Tighten four stainless steel M6 screws of appropriate head size and length not supplied at the four outer holes on the locking base of the Easy Mount...

Page 5: ...kwise until tight to tighten the movable plate of the Easy Mount Make sure the light is locked in place 6 Connect the power to the light according to the instructions in the Connecting Power to the Light section The light is ready to use Dismounting the Light from Easy Mount 1 Disconnect power from the light 2 Turn knob of the locking bolt counterclockwise to loosen the movable plate of the Easy M...

Page 6: ... the bottom edge will come on This indicator light will become green when charging is complete Unplug the USB cable Charing the remote control only when the red light starts to blink will extend the useful life of the rechargeable battery A rechargeable battery is usually good for about 1 000 charges Power ON OFF Remote While the remote control is off press and hold Remote Control Power Switch unt...

Page 7: ...he two groups can be selected individually or together When a group selection button is on selected the remote control functions will apply to all of the lights included in that group NOTE While a remote control can pair with many lights a light can be paired with one Select Group button of one remote control Always send a light together with its paired remote control If a light is paired with a n...

Page 8: ...light under the chosen Select Group of Lights button will blink f Press Remote Control Power Switch once The red indicator light under the chosen Select Group of Lights button will become steady g Press remote Control Power Switch again The light will be off and starts its self reset process The programming is finished h TEST SETUP Use the remote control to operate the light with the chosen group ...