background image

Larson Electronics, LLC

 

Phone: (877) 348-9680

 Fax: (903) 498-3364 

  www.larsonelectronics.com 

2

 of 

2

 

EPL-16C-1MLED-300

 

This unit comes pre-wired from factory with the selected cord cap. Take precautionary steps for 

weatherproofing all connections if installed in a location where water may come in contact with the unit. All 

outdoor installations and indoor installations near a wet location require the use of a GFCI device for safety, 

according to the National Electrical Code® (NEC). Ensure the unit is properly grounded.

Position device near work area for operation. Run cable to nearby power source. Insert and twist-lock 

explosion-proof plug into a compatible receptacle within the hazardous environment. See plug operation 

below.

WARNING:

 

check nameplate for proper voltage. Damage from improper voltage may void warranty.

PLUG OPERATION

Electrical connection between plug and compatible receptacle is accomplished after plug fully inserts into 

receptacle and is rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

 

receptacle face. Insert plug straight all 

the way into receptacle until it

 

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

 

completes circuit. This also 

mechanically locks plug into receptacle so it

 

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

 

straight out.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

any

 

warranty. 

1.

Perform visual, mechanical and electrical inspections on a regular basis. We recommend routine

 

checks to be made on a yearly basis. Frequency of use and environment should determine this.  It is

 

recommended to follow an Electrical Preventive Maintenance Program as described in NFPA 70B:

 

Recommended practice for Electrical Equipment.

2.

The lens should be cleaned periodically as needed to ensure continued photometric performance.

 

Clean the lens with a damp, non-abrasive, lint-free cloth. If not sufficient, use mild soap or a liquid

 

cleaner.

3.

Inspect the cooling fins on the luminaire to ensure that they are free of any obstructions or

 

contamination (i.e. excessive dust build-up). Clean with a non-abrasive cloth if needed.

4.

Do not operate if the lens is cracked or damaged. All fasteners should be properly seated.

USE AND CARE

Unauthorized modification may impair the function and/or safety of this device and could affect the life of the equipment. 

Always check for damaged or worn out parts before using the device. Store it in a secure place out of the reach of 

children when not in use. Inspect for good working condition prior to storage and before re-use.

 

 

REPLACEMENT PARTS

The 

EPL-16C-1MLED-300

 is designed to provide years of reliable performance. Should the need for replacement parts 

arise, please contact Larson Electronics. 

THESE INSTRUCTIONS MAY  NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. 

SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

 OR BY PHONE AT 

1-877-348-9680

 FOR FURTHER ASSISTANCE. 

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

 AND 

RETURN

 INFORMATION.

Reviews: