102
Explosion Proof Network IP Camera User Manual
6.
Set the time threshold, detection sensitivity and object percentage for intrusion
detection.
Threshold:
Range [0s-10s], the threshold for the time of the object loitering in
the region. If you set the value as 0, alarm is triggered immediately after the
object entering the region.
Sensitivity:
Range [1-100]. The value of the sensitivity defines the size of the
object which can trigger the alarm. When the sensitivity is high, a very small
object can trigger the alarm.
Percentage:
Range [1-100]. Percentage defines the ratio of the in-region part of
the object which can trigger the alarm. For example, if the percentage is set as
50%, when the object enters the region and occupies half of the whole region, the
alarm is triggered.
7.
Repeat the above steps to configure other regions. Up to 4 regions can be set. You
can click the
Clear
button to clear all pre-defined regions.
8.
Click the
Edit
button to set the arming schedule.
9.
Select the linkage methods for intrusion detection, including Notify Surveillance
Center, Send Email, Upload to FTP, Trigger Channel and Trigger Alarm Output.
10.
Click
Save
to save the settings.
Figure 6-63 Configuring Intrusion Area