1. INTRODUCTION

Larson Electronics specializes in converting Single Phase electrical power to Three Phase 

electrical power. The diagram below provides a very simple view of the layout. 

An additional 3-phase breaker panel may be installed on the line between the converter control 

panel and the 3-phase equipment.  This is recommended to protect each piece of equipment and 

the wire that feeds that equipment. 

The two single phase lines pass through the phase converter and are used to manufacture the 3

rd

 

line that completes the three phases.  The output voltage will always be close to the input voltage.  

If  a  completely  different  voltage  is  needed  then  a  transformer  installed  in  front  of  the  phase 

converter will be necessary. 

The  three-phase  output  is  delta  configured.  This  means  that  voltage  measurements  between 

phases will be similar to input voltages. 

Voltages should only be measured line to line.  Do not 

measure voltages line to ground

.

 Most machinery requires a delta three phase voltage and this 

third line voltage to ground should not affect operation.  If a piece of equipment requires wye voltage 

and  a  neutral  connection,  the  output  of  the  phase  converter  must  be  run  through  a  delta-wye 

transformer to create the neutral.  The phase converter must be started before the transformer is 

connected  electrically.    This  is  done  with  a  safety  disconnect  switch.    Larson  Electronics  can 

provide these transformers and disconnect switches. 

Summary of Contents for 240 VOLT SERIES

Page 1: ...ALL PURPOSE CNC HEAVY DUTY Rotary Phase Converters 240 480 VOLT SERIES Smart Digital Phase Converter Operation Installation Manual MTPC DRB 208 240 1P 20HP 3P...

Page 2: ...ether and insulated 4 7 5 8 6 9 Do not use wire nuts or ground any of these connections Use the supplied bolts and make all connections insulated Make sure the Phase Converter Panel the Idler Motor an...

Page 3: ...different voltage is needed then a transformer installed in front of the phase converter will be necessary The three phase output is delta configured This means that voltage measurements between phase...

Page 4: ...g 50 degrees C High humidity 2 1 2 INSTALLATION GUIDELINES CONTROL PANEL IDLER Steps to install the control panel and idler a Mount enclosure on a secure wall or on the idler idler mount models only A...

Page 5: ...losure cover is used for clarity f Wire the idler 240V Bolt idler leads 4 5 6 together Insulate this connection with electrical tape or heat shrink tubing Connect the ground line to the ground screw i...

Page 6: ...otect all wire and machinery with proper size breakers Always make sure rotary phase converter starts before external load s are applied A qualified electrician should do all wiring DO NOT assume that...

Page 7: ...minimum recommended based on largest hard starting CNC amps For combined HP s greater than 50 of maximum total HP listed in the tables above consult NEC local codes for conductor sizing The above cha...

Page 8: ...ner by turning the switch to the stop position As with most electrical equipment frequent stops and starts are harder on the rotary phase converter than steady operation The rotary phase converter is...

Page 9: ...tically start loads after the converter reaches full speed 3 3 1 MAINTENANCE Keep dust and moisture from the control panel and the idler Keep dust from accumulating in the motor Dust can be blown out...

Reviews: