If this phase converter does not start in less than 2 seconds, 

TURN IT OFF!

 

1. Make sure the wire size meets our minimum recommended size.

2. All loads INCLUDING TRANSFORMERS must be DISCONNECTED before starting the phase converter

each time.  This includes small control transformers that run controls inside your equipment.  If you need an
economical 3-phase disconnect switch, please visit 

www.larsonelectronics.com

 or call 1-800-369-6671

for assistance.

If your converter still takes more than 2 seconds to start, call our Toll-Free Technical support line 

1-800-369-6671.  You will be asked to verify conditions 1 and 2 above are met.  Failing to meet these two 

condition account for 99% of starting problems and can result in damage to the starting capacitors. 

This converter is quiet. If it does not sound quiet and smooth, 

TURN IT OFF!

 

3. Make sure the idler motor is mounted on rubber.  

DO NOT BOLT THE IDLER MOTOR DOWN!

  This can

cause bearing failure.

4. Make sure the idler motor is wired properly.

For the Larson Electronics soft-start idler motor 

240 Volts Input (1, 7, A), (2, 8, B), (3, 9, C), (4, 5, 6 bolted together and insulated).  

480 Volts Input (1, A), (2, B), (3, C). The following bolted together and insulated: (4, 7), (5, 8), (6, 9) 

Do not use wire nuts or ground any of these connections. Use the supplied bolts and make all 

connections insulated. 

* Make sure the Phase Converter Panel, the Idler Motor, and your equipment is grounded!

5. This phase converter does NOT disconnect the single phase power as it passes through the unit, so the

single phase legs remain energized even when the rotary phase converter is off.  In addition to installing a

single phase breaker in front of the phase converter, you need to be aware that the single phase power

DOES flow through the phase converter whether the unit is on or off.

6. Before connecting load, verify proper function of phase converter. This will ensure the protection of the

phase converter and your equipment.

 

For a stock three-phase motor

 that uses our Stock Motor Panel, wire 

the motor according to the diagram for that motor, 

NOT

 according to our wiring diagram. 

DANGER

:  HIGH VOLTAGE 

Electric shock could result in death or injury.  Please 

consult qualified personnel for installation.

 

DANGER

:  Risk of Electric Shock 

Please wait 30 minutes before servicing 

This manual is to serve the purpose of providing recommendations for proper performance, 

but is not to supersede or replace local or national electric codes. Installation should be done 

by a licensed electrician who is familiar with phase converter installations.

Summary of Contents for 240 VOLT SERIES

Page 1: ...ALL PURPOSE CNC HEAVY DUTY Rotary Phase Converters 240 480 VOLT SERIES Smart Digital Phase Converter Operation Installation Manual MTPC DRB 208 240 1P 20HP 3P...

Page 2: ...ether and insulated 4 7 5 8 6 9 Do not use wire nuts or ground any of these connections Use the supplied bolts and make all connections insulated Make sure the Phase Converter Panel the Idler Motor an...

Page 3: ...different voltage is needed then a transformer installed in front of the phase converter will be necessary The three phase output is delta configured This means that voltage measurements between phase...

Page 4: ...g 50 degrees C High humidity 2 1 2 INSTALLATION GUIDELINES CONTROL PANEL IDLER Steps to install the control panel and idler a Mount enclosure on a secure wall or on the idler idler mount models only A...

Page 5: ...losure cover is used for clarity f Wire the idler 240V Bolt idler leads 4 5 6 together Insulate this connection with electrical tape or heat shrink tubing Connect the ground line to the ground screw i...

Page 6: ...otect all wire and machinery with proper size breakers Always make sure rotary phase converter starts before external load s are applied A qualified electrician should do all wiring DO NOT assume that...

Page 7: ...minimum recommended based on largest hard starting CNC amps For combined HP s greater than 50 of maximum total HP listed in the tables above consult NEC local codes for conductor sizing The above cha...

Page 8: ...ner by turning the switch to the stop position As with most electrical equipment frequent stops and starts are harder on the rotary phase converter than steady operation The rotary phase converter is...

Page 9: ...tically start loads after the converter reaches full speed 3 3 1 MAINTENANCE Keep dust and moisture from the control panel and the idler Keep dust from accumulating in the motor Dust can be blown out...

Reviews: