2 Installation
Package Contents
Check the package contents to make sure you have received the following items. Contact your sales
representative if any item is damaged or missing. Please save the packaging for possible future use.
•
One SM24TBT2DPA Switch with one AC Power Supply Module
•
One Support Postcard (33504)
•
One printed Quick Start Guide (33736)
•
One DB9F to RJ45 Cable (6WPDB92RJ453)
•
Four Rubber Feet (6RR2005AB4B2)
•
Two Brackets (6EFS226C0E09)
•
Eight Screws (6PF+UN3X5000)
Note
: The switch is an indoor device. If it is to be used with outdoor devices such as outdoor IP cameras or
outdoor WAPs, then it is strongly suggested you install a surge protector or surge suppressor in order to protect
the switch.
Safety Instructions for Rack Mount Installations
The instructions below (or similar) are intended for rackmount installation environments:
1.
Elevated Operating Ambient: if installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may exceed room ambient. Install the equipment in an environment
compatible with the maximum ambient temperature (Tma) specified.
2.
Reduced Air Flow: install the equipment in a rack so that the amount of air flow required for safe operation is
not compromised.
3.
Mechanical Loading: Mount the equipment in the rack so that a hazardous condition does not occur due to
uneven mechanical loading (weight distribution/rack balance).
4.
Circuit Overloading: consider the connection of the equipment to the supply circuit and the effect that
overloading of the circuits might have on overcurrent protection and supply wiring. Consider all equipment
nameplate ratings when addressing this concern.