background image

Lantronix

 

 

SM24TBT2DPA Install Guide

 

33737 Rev. L 

                 

https://www.lantronix.com/

   

Page 

10

  of 

38

 

 

Egress shaping and rate control 

 

Per port 

Management 

DHCP Server 

Support DHCP server to assign IP to DHCP clients 

DHCP per Port 

You can assign an IP address based on the switch port the device is connected to.   
This will speed up installations of IP cameras; cameras can be configured after they 
are on the network. The per-port assignment allows you to know which IP was 
assigned to which camera. 

Link-Local Address 
binding interface 

Configure Link-Local IP address to a different VLAN interface. The first IP interface 
entry (169.254.xx.xx) is for the default value (VLAN 1). A link-local address is a unicast 
address having link-only scope that can be used to reach neighbors. All interfaces on 
routers must have a link-local address. Also, ADDRCONF requires that interfaces on 
hosts have a link-local address. 

Event Notifications 

 

Event Notification via Syslog and/or SNMP Traps 

 

Event Notification with 8 Severity levels 

Remote Monitoring 
(RMON) 

Embedded RMON agent supports RMON groups 1,2,3,9 (history, statistics, alarms, 
and events) for enhanced traffic management, monitoring and analysis 

Port Mirroring 

Traffic on a port can be mirrored to another port for analysis with a network analyzer 
or RMON probe. Up to 

n

-1 (where 

n

 is the max number of Switch Ports) ports can be 

mirrored to single destination port. A single session is supported.     

UPnP 

The Universal Plug and Play Forum was formed to standardize discovery and control 
of networked devices. See the Open Connectivity Foundatio

webpage

. 

s-Flow 

The industry standard for monitoring high speed switched networks. It gives complete 
visibility into the use of networks enabling performance optimization, 
accounting/billing for usage, and defense against security threats   

IEEE 802.1ab (LLDP)   

 

Used by network devices for advertising their identities, capabilities, and 

neighbors on an IEEE 802ab local area network 

 

Support LLDP-MED extensions 

Web GUI Interface 

Built-in switch configuration utility for browser-based device configuration   

CLI 

For configuring / managing switch in Command Line Interface modes 

Dual Image 

Independent primary and secondary images for backup while upgrading   

SNMP   

SNMP version1, 2c and 3 with support for traps, and SNMP version 3 user-based 
security model (USM) 

Firmware Upgrade 

 

Web browser upgrade (HTTP/ HTTPs) and TFTP 

 

Upgrade via the console port   

NTP 

Network Time Protocol (NTP) is a networking protocol for clock synchronization 

between computer systems over packet-switched 

Summary of Contents for SM24TBT2DPA

Page 1: ...SM24TBT2DPA Managed Gigabit Ethernet PoE Switch Install Guide Part Number 33737 Revision L December 2022...

Page 2: ...ding title non infringement fitness quality accuracy completeness usefulness suitability or performance of the information provided herein Lantronix shall have no liability whatsoever to any user for...

Page 3: ...cifications 18 Unpacking Installing Replacing Power Supplies 20 Unpacking Power Supply 20 Installing a Power Supply 21 Replacing a Power Supply 22 Connecting the AC Power Cord 22 Power Disconnection 2...

Page 4: ...and includes 1 AC power supply and 19 rack mount brackets About This Manual This manual describes how to install initially configure and troubleshoot the SM24TBT2DPA Switch including Install the switc...

Page 5: ...ch delivers advanced functionality in a L2 managed switch including Layer 3 static route DHCP server Ipv6 support LLDP etc It also has comprehensive security features such as IP source guard and ACL t...

Page 6: ...renheit Centigrade Fahrenheit Centigrade Feet Meters 32 to 104 0 to 40 4 to 158 20 to 70 10000 3000 Dimensions Weight Humidity Dimensions W x D x H Weight Operating Humidity Millimeters Inches Kilogra...

Page 7: ...ply Each of Port 1 24 supports PoE PoE PoE within available Power One Power Supply 820W PoE Power with one 920W Power Supply module 1640W with two Power Supplies Two Power Supplies 1640W PoE Power wit...

Page 8: ...oups IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router IGMP Proxy IGMP snooping with proxy reporting or report suppressi...

Page 9: ...mber of learned MAC address IP Source Guard Prevents illegal IP address from accessing to specific port in the switch RADIUS TACACS Supports RADIUS and TACACS authentication Switch as a client Storm C...

Page 10: ...lysis Port Mirroring Traffic on a port can be mirrored to another port for analysis with a network analyzer or RMON probe Up to n 1 where n is the max number of Switch Ports ports can be mirrored to s...

Page 11: ...nk status of PDs and reboots PDs if there are no responses Power Delay The switch provides power to the PDs based on configurable delay time when PoE switch boots up in order to protect switch from mi...

Page 12: ...g temperature range has been detected in the switch Mode LEDs indicate the mode of all RJ45 SFP ports on the switch You can press the Mode button sequentially to switch between the two different modes...

Page 13: ...100Mbps Off The port has no active network cable connected or it is not established a link to connected device Otherwise the port may have been disabled through the switch user interface SFP Ports Gr...

Page 14: ...formed by reading the LED behaviors while pressing and holding the Mode Reset button When the LED behavior displays correctly release the button Table 4 Mode Reset Button Descriptions Task to Perform...

Page 15: ...ct the switch Safety Instructions for Rack Mount Installations The instructions below or similar are intended for rackmount installation environments 1 Elevated Operating Ambient if installed in a clo...

Page 16: ...nch Rack 1 Attach the mounting brackets to both sides of the chassis Insert screws and tighten with a screwdriver to secure the brackets 2 Place the switch on a rack shelf in the rack Push it in until...

Page 17: ...allation and maintenance avoid direct exposure to laser beams Specifically do not look into laser ports Ensure that each SFP port at which laser beams are or will be present is occupied by an SFP that...

Page 18: ...Redundancy Dual Hot Swappable Power Supplies Power Supply Efficiency The power supply efficiency will be higher than 80Plus Silver 230VAC internal specification without fan loading Input voltage 20 o...

Page 19: ...uld be over voltage protected The output should never exceed 60V on the 54 5V output Minimum Typical Maximum OVP 57 3V 58 65V 60V Over current protection OCP The outputs should be over current protect...

Page 20: ...he switch ships with one power supply 820 Watts standard order the second Power Supply for an additional 820 Watts Note The switch supports dual redundant power supplies and they are hot swappable You...

Page 21: ...ne power supply it can be installed in either power supply bay and the Face Plate must be installed in the other bay 1 Remove the blank Face Plate to use the one open Power Supply slot Save the Face P...

Page 22: ...ver clicks 3 Continue with Connecting the AC Power Cord below Connecting the AC Power Cord 1 Connect the AC power cord to the switch AC power receptacle 2 Use the Power Cord Retainer if desired 3 Conn...

Page 23: ...mendment to IEEE Std 802 3 2015 increases the maximum PD power available by utilizing all four pairs in the specified structured wiring plant This represents a substantial change to the capabilities o...

Page 24: ...mple for a PC running Windows 7 8 x 10 is 2a Type network and sharing into the Search box in the Start Menu 2b Select Network and Sharing Center 2c Click on Change adapter settings on the left of PC s...

Page 25: ...page 7 Click Login to log into the switch See the Web User Guide for additional information Initial Switch Configuration via CLI Use an RJ 45 cable to connect a terminal or PC terminal emulator to th...

Page 26: ...CLI try configuring testing via the Web UI and vice versa See the Web User Guide or the CLI Reference LED Summary Category LED Color Function Global System Alarm Green LED Off The switch is not receiv...

Page 27: ...ange and take corresponding actions to resolve Port Status LED is Off in Link Act Speed Mode The port is not connected or the connection is not working 1 Check if the cable connector plug is firmly in...

Page 28: ...t has negotiated with the switch 6 Check the type and length of the cabling for any effect on the electrical characteristics and impact on the amount of power drawn on a port 7 Investigate the power n...

Page 29: ...3 PoE Source is outdoor PD is outdoor Env B Option 3 is the most challenging environment since both the PD and PSE are installed outdoors Caution The switch is an indoor device If it is to be used wit...

Page 30: ...mix POE and non POE devices on the same POE switch i e you can put PCs on the same POE switch as a SIP phone or a VOIP phone The PSE your switch will only send power if requested by the PD Ethernet an...

Page 31: ...of PoE e g for PoE See the ANSI NECA BICSI 568 2006 Standard for Installing Commercial Building Telecommunications Cabling ANSII NECA BICSI 568 describes minimum requirements and procedures for instal...

Page 32: ...etc ________________ ________________________________________________________________________________________________________________________ __________________________________________________________...

Page 33: ...es Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undes...

Page 34: ...4 3 2008 ED 2 0 EN 6100 4 3 2006 A1 2008 A2 2010 IEC 61000 4 3 2010 ED 3 2 EN 61000 4 4 2012 IEC 61000 4 4 2012 ED 3 0 EN 61000 4 5 2006 IEC 61000 4 5 2005 ED 2 0 EN 61000 4 6 2014 IEC61000 4 6 2013 E...

Page 35: ...y taken to resolve the problem e g changing DIP switch setting etc _________________________________________________________________________________________ ___________________________________________...

Page 36: ...The power module has a provision for grounding Equipment grounding is vital to ensure safe operation The installer must ensure that the power module is properly grounded during and after installation...

Page 37: ...riften worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti...

Page 38: ...uite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Tel 1 800 526 8766 Tel 1 949 453 3990 or https www lantronix com technical support Sales Offic...

Reviews: