SCS100/200/400 User Guide
6: Application Setup
a) Click
the
Modems
or
Back to Modems
link.
b) Enter the IP pool address range for remote users.
Note:
The IP pool range must be in the same subnet range as the SCS IP
address and cannot be used by any other device on the network. If only one
modem is connected to the SCS, then only one IP address is required for the
pool. For this configuration, enter the same IP address in the Start and End
fields.
5.
Reboot the SCS for the pool range settings to take effect.
Event Port Logging and Email Notification
You can configure each SCS serial port to store its console output in a log file. If email
notification is also enabled, a system administrator receives an email through an SMTP
mailserver if the connected device reboots or otherwise produces a burst of console
output.
To enable email notification, configure the features discussed in the following sections.
For more information on any of these features, see the
SCS Reference Manual
.
To enable port event logging:
1.
Click the
Ports
link under Advanced Settings.
2.
Click
Configure
next to the desired serial port.
6-11