Tunnel – Packing Mode Page
When tunneling, data can be packed (queued) and sent in large chunks on the network
instead of being sent immediately after being read on the serial line. If you click
Packing
Mode
at the top of one of the Tunnel pages, the Tunnel – Packing Mode page displays.
Here you can select packing settings for the tunnel selected at the top of the page. For
more information about Packing Mode, see
Packing Mode
.
Figure 7-11 Tunnel – Packing Mode Page
Table 7-9 Tunnel – Packing Mode Page
Tunnel – Packing
Mode Page
Settings
Description
Mode
Select the method used to pack data. Choices are:
Disabled
= data is never packed. (default)
Timeout
= data is sent after the timeout elapses.
Send Character
= data is sent when the send character is read on
the serial line.
Timeout
Enter the maximum number of milliseconds to wait before sending
queued data across the network. Default is 1000 milliseconds.
Threshold
Enter the queued data limit that, when reached, immediately sends
queued data to the network. Default is 512 bytes.
Send Character
Enter the send character. When this character is read on the serial
line, it forces the queued data to be sent immediately. Default is
<none>.
Trailing Character
Enter the trailing character. This character is inserted into the
outgoing data stream immediately after the send character. Default is
<none>.
Summary of Contents for I/O 2100
Page 1: ...Part Number 900 474 Revision B March 2012 IntelliBox I O 2100 User Guide ...
Page 36: ...5 Getting Started IntelliBox I O 2100 User Guide 36 Figure 5 1 Lantronix DeviceInstaller ...
Page 86: ...9 Services Settings IntelliBox I O 2100 User Guide 86 Figure 9 7 HTTP Configuration Page ...
Page 95: ...10 Security Settings IntelliBox I O 2100 User Guide 95 Figure 10 1 SSH Server Host Keys Page ...
Page 123: ...12 Advanced Settings IntelliBox I O 2100 User Guide 123 Figure 12 3 Email Configuration Page ...