13: Connections
EMG™ Edge Management Gateway User Guide
285
3. To save, click the
Apply
button.
To view, update, or disconnect a current connection:
The bottom of the
page displays current connections.
Figure 13-7 Current Connections
1. To view details about a connection, hold the mouse over the arrow in the
Flow
column.
2. To disconnect (delete) a connection, select the connection in the
Select
column and click the
Terminate
button.
3. To reestablish the connection, create the connection again in the top part of the page.
4. To view information about Web connections, click the
here
link in the text above the table. The
Maintenance > Firmware & Configurations
page displays.
Connection Commands
Go to
to view CLI commands which correspond to the web page entries
described above.
Port
If the
to
field is set to
Device Port
or
Modem on Device Port
, enter the number of the
device port. For all other options, this is the TCP/UDP port number, which is optional for
Telnet out and SSH out, but required for TCP Port and UDP Port.
Note:
If you select
Device Port
, it must not have command line interface logins
enabled or be running a loopback test. To view the device port's settings, click the
Settings
link to the right of the port number.
SSH Out
Options
Select one of the following optional flags to use for the SSH connection.
User:
Login ID to use for authenticating on the remote host.
Version:
Version of SSH. Select 1 or 2.
Command:
Enter a specific command on the remote host (for example, reboot).
Trigger
Select the condition that will trigger a connection. Options include:
Connect now:
Connects immediately, or if you reboot the EMG, immediately on
reboot.
Connect at date/time:
Connects at a specified date and time. Use the drop-down
lists to complete the date and time. Upon rebooting, the EMG unit reestablishes the
connection if the date/time has passed.
Auto-connect on characters transferring:
Select the arrow indicating the direction
of the data transfer and either the minimum number of characters or a specific
character sequence that will trigger the connection.
You can select the direction of the data transfer only if
Data Flow
is bidirectional. Upon
rebooting, the EMG does not reestablish the connection until the specified data has
passed through one of the endpoints of the connection.
Summary of Contents for EMG 7500
Page 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Page 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Page 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Page 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...