8: Services
EMG™ Edge Management Gateway User Guide
153
Top Level MIB
(link)
Click the link to access the top level MIB file for all Lantronix products.
EMG MIB (link)
Click the link to access the EMG MIB definition file for EMGs.
EMG MON MIB
(link)
Click the link to access the EMG monitor MIB definition file for EMGs.
Enable v1
If checked, SNMP version 1 (which uses the Read-Only and Read-Write Communities)
is enabled. The default is disabled.
Enable v2c
If checked, SNMP version 2c (which uses the Read-Only and Read-Write
Communities) is enabled. The default is enabled.
Enable Traps
Traps are notifications of certain critical events. Disabled by default. This feature is
applicable when SNMP is enabled.
Traps that the EMG unit sends include:
coldStart (generic trap 0, OID 1.3.6.1.6.3.1.1.5.1)
linkDown (generic trap 2, OID 1.3.6.1.6.3.1.1.5.3)
linkUp (generic trap 3, OID 1.3.6.1.6.3.1.1.5.4
authenticationFailure (generic trap 4, OID 1.3.6.1.6.3.1.1.5.5)
slcEventPowerSupply (1.3.6.1.4.1.244.1.1.0.1)
slcEventSysadminPassword (1.3.6.1.4.1.244.1.1.0.2)
slcEventSLCShutdown (1.3.6.1.4.1.244.1.1.0.3)
slcEventDevicePortData (1.3.6.1.4.1.244.1.1.0.4)
slcEventDevicePortSLMData (1.3.6.1.4.1.244.1.1.0.5)
slcEventDevicePortSLMConfig (1.3.6.1.4.1.244.1.1.0.6)
slcEventDevicePortDeviceLowTemp (1.3.6.1.4.1.244.1.1.0.7)
slcEventDevicePortDeviceHighTemp (1.3.6.1.4.1.244.1.1.0.8)
slcEventDevicePortDeviceLowHumidity (1.3.6.1.4.1.244.1.1.0.9)
slcEventDevicePortDeviceHighHumidity (1.3.6.1.4.1.244.1.1.0.10)
slcEventDevicePortDeviceError (1.3.6.1.4.1.244.1.1.0.11)
slcEventUSBAction (1.3.6.1.4.1.244.1.1.0.14)
slcEventInternalTemp (1.3.6.1.4.1.244.1.1.0.13)
slcEventDevicePortError (1.3.6.1.4.1.244.1.1.0.15)
slcEventSDCardAction (1.3.6.1.4.1.244.1.1.0.16)
slcEventNoDialToneAlarm (1.3.6.1.4.1.244.1.1.0.17)
slcEventDevicePortDeviceContactChanged (1.3.6.1.4.1.244.1.1.0.20)
slcEventSFPAction (1.3.6.1.4.1.244.1.1.0.21)
slcEventNoDialToneAlarm (1.3.6.1.4.1.244.1.1.0.17)
slcEventRPMAction (1.3.6.1.4.1.244.1.1.0.18)
slcEventPingHostFails (1.3.6.1.4.1.244.1.1.0.19)
slcEventDevicePortDeviceContactChanged (1.3.6.1.4.1.244.1.1.0.20)
slcEventSFPAction (1.3.6.1.4.1.244.1.1.0.21)
slcEventDevicePortAction (1.3.6.1.4.1.244.1.1.0.22)
slcEventNetworkFailover (1.3.6.1.4.1.244.1.1.0.23)
slcEventVPNTunnel (1.3.6.1.4.1.244.1.1.0.24)
slcEventDIOPortAction (1.3.6.1.4.1.244.1.1.0.25)
slcEventWireless (1.3.6.1.4.1.244.1.1.0.26)
The EMG unit sends the traps to the host identified in the
NMS #1
and
NMS #2
field
using the selected
Trap Version
.
For information on these traps, view the EMG enterprise MIB, which is available on the
SNMP web page.
Note:
When the DSR signal drops on a device port, indicating that the attached cable
has been disconnected or the attached device has been powered off, the EMG will log
the event in the Device Ports system log and send a slcEventDevicePortAction
SNMP trap. The log message and SNMP trap only occur if there is an active (connect
direct or network connection) to the device port.
Summary of Contents for EMG 7500
Page 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Page 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Page 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Page 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...