5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
115
default local port
Uses a random port number as the local port for
establishing tunneling connections to other devices.
default reconnect time
Restores the default reconnect time value for
connect mode tunneling.
default start character
Defaults the connect mode start character.
email connect
<number>
Sets an email profile to use to send an email alert
upon establishing a connect mode tunnel.
<number> = the number of the email profile to use.
email disconnect
<number>
Sets an email profile to use to send an email alert
upon closing a connect mode tunnel. <number> =
the number of the email profile to use.
exit
Returns to the tunnel level.
flush serial disable
Characters already in the serial data buffer are
retained upon establishing a connect mode
tunneling connection.
flush serial enable
Flushes the serial data buffer upon establishing a
connect mode tunneling connection.
flush start character disable
Enables forwarding of the connect start character
into the network.
flush start character enable
Disables forwarding of the connect start character
into the network.
host
<instance>
Enters the next lower level. Specify the instance for
the next lower level.
host mode sequential
Connects to the first host in the list that accepts the
connection.
host mode simultaneous
Selects simultaneous connections to all hosts on the
host list.
kill connection
Disconnects the active connect mode tunneling
connection or connections.
local port
<number>
Sets a specific port for use as the local port.
<number> = the number of the port to use.
no email connect
Discontinues sending email alerts upon establishing
a connect mode tunnel.
no email disconnect
Discontinues sending email alerts upon closing a
connect mode tunnel.
promote host
<number>
Promotes the identified host, exchanging it place
with the host above it, to adjust the order of the
defined hosts.
reconnect time
<milliseconds>
Sets the reconnect time value for tunneling
connections established by the device in
milliseconds. <milliseconds> = timeout in
milliseconds.
show
Displays the current configuration.
show history
Displays the last 20 commands entered during the
current CLI session.
show status
Displays tunnel connect status.
start character
<control>
Sets the connect mode start character. The
character may be input as text, control, decimal, or
hex. A control character has the form <control>C. A
decimal value character has the form \99. A hex
value character has the form 0xFF.