Advanced protection in UW-MTX 3.5/3.5EC/3.5H/4.5 Series
Under Current
Current Unbalance
Under Voltage
Over Voltage
Parameter
Protection: Enable/Disable
Pick-Up=lr x ...
Delay
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up=ln x ...
Delay
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up(Vs)=Vn x ...
Delay
Vs reset
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up(Vs)=Vn x ...
Delay
Vs reset
UW-MTX 4.5
Mode: Trip/Alarm/Both
0.2 to 0.8 in step of 0.05
1 to 255sec in step of 1sec
10 to 90% in step of 5%
500 ms to 60s in step of 0.5s
0.7 to 0.95 in steps of 0.01
100 ms to 5s in step of 100 ms
1.01/1.02/1.03/1.04 x Vs
1.05 to 1.5 Vn in step of 0.01
100 ms to 5s in steps of 100 ms
0.95 to 0.99 Vs in step of 0.01
Voltage Unbalance
Residual Voltage
Under Frequency
Over Frequency
Rev Power
Earth Leakage**
Restricted EF**
Protection: Enable/Disable
Pick-Up(Vs)=Vn x ...
Delay
Vs reset
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up (Vs)=Vn x ...
Delay
Vs Reset
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up (Fn)
Delay
Reset Freq
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up (Fn)
Delay
Reset Freq
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up=Pn x ...
Delay
Mode: Trip/Alarm/Both
Mode: Trip/Alarm/Both
Protection: Enable/Disable
Pick-Up(lr)
Delay
Protection: Enable/Disable
2
I t: OFF/ON
Pick-Up(lg)=ln x ...
2
l t OFF (tg)
2
l t ON (tg)
Pre-alarm
Cold Pick-Up: ON/OFF
5 to 20% in step of 1%
500ms to 60s in step of 0.5s
0.95 to 0.99 Vs in step of 0.01
0.15/0.2/0.25/0.3/0.4
100ms to 5s in step of 100 ms
0.95 to 0.99 Vs in step of 0.01
45-50 Hz in step of 0.1Hz
1-30sec in step of 0.1sec
1.01 to 1.05 Fn in step of 0.01
50-55 Hz in step of 0.1 Hz
1-30sec in step of 0.1sec
0.95 to 0.99 Fn in step of 0.01
0.05 to 0.4 in step of 0.01
100ms-20s in step of 0.1s
0.3 to 30A in step of 0.1 A
100-200-300-400-500 ms
0.1 to 0.6 in step of 0.1
100 ms to 5sec in step of 0.1s
100-200-300-400 ms
0.5 to 0.95 in step of 0.05 x lg
60 ms to 10s in step of 20ms
Mode: Trip/Alarm/Both
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
UW-MTX3.5EC
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
35
Matrix
Protection and Control Units
* Requires Power Metering module for
**
Advanced Voltage based Protection
Requires additional modules
UW-MTX3.5*
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Available
UW-MTX3.5H
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
Summary of Contents for OMEGA
Page 2: ...Stabilise systems with technology ...
Page 4: ...Change course quickly ...
Page 6: ...Match performance with prudence ...
Page 8: ...Adopt technological brilliance ...
Page 10: ...Keep an eye on upkeep ...
Page 26: ...Matrix Protection Control Units T UW M X4 5 ...
Page 70: ...Accessories ...
Page 84: ...Control Circuit Wiring ...
Page 92: ...Mounting Termination ...
Page 135: ...SP 50567 R5 ...