Data Sheet
AB00A.C13
landiaworld.com
Prepared by: BNV/GB
Approved by: KSK/TM
Issued on: 1 January 2018
Rev. date: 20. May 2021
ELECTRICAL DATA
Page 4/5
Motor type
3-phase AC motor
Nominal voltage
400 V
Minimum voltage allowed
360 V
Nominal frequency
50 Hz
Applicable for VFD operation
Yes
Ingress protection rating
IP 68
Insulation class
F
Start function
Soft starter required
ATEX classification
II 2 G Ex db h IIB T4 Gb (Option, only available for specific models)
M
o
d
e
l
It
e
m
n
u
m
b
e
r
N
o
m
in
a
l p
o
w
e
r
M
o
to
r
F
u
ll
lo
a
d
c
u
rr
e
n
t
(4
00
V
)
Co
n
n
e
ct
io
n
m
e
th
o
d
St
a
rt
cu
rr
e
n
t
(D
O
L
)
co
s p
h
i
E
ff
ic
ie
n
cy
[kW]
[rpm]
[A]
Y/∆
[A]
[%]
POPL-I 1.5/1.1 kW-22 rpm, ø1,700 IE2
1636601
3.0
955
7.1
Δ
50
7.3
83.3
POPL-I 2.2/1.5 kW-34 rpm, ø1,700 IE2
1634602
2.2
1,455
4.8
Y
45
0.77
84.3
POPL-I 3.0/2.2 kW-34 rpm, ø1,700 IE2
1634603
3.0
1,460
6.5
Δ
63
0.77
85.5
POPL-I 4.0/3.0 kW-47 rpm, ø1,700 IE2
1634604
4.0
1,460
7.6
Δ
63
0.86
87.6
POPL-I 7.5/4.0 kW-47 rpm, ø1,700 IE2
1634607
7.5
1,470
14.5
Δ
123
0.82
89.9
POPL-I 2.2/1.5 kW-19 rpm, ø2,300 IE2
1536502
3.0
955
7.1
Δ
50
7.3
83.3
POPL-I 3.0/2.0 kW-22 rpm, ø2,300 IE2
1536503
3.0
955
7.1
Δ
50
0.73
83.3
POPL-I 4.0/3.0 kW-34 rpm, ø2,300 IE2
1534504
4.0
1,460
7.6
Δ
63
0.86
87.6
POPL-I 7.5/4.0 kW-34 rpm, ø2,300 IE2
1534507
7.5
1,470
14.5
Δ
123
0.82
89.9
For voltages others than 400 V/50 Hz please refer to the attached Appendix.