AA01B.C01
Service instruction POPR-I
Page 6/7
Prepared by: ALJ/CML
Issued on: 01 March 1997
Approved by: SL
Rev. date: 12 March 2021
Oil control
The oil is controlled by removing the upper oil plug, pos. A. The oil has to be clean and the level has to reach the plug
hole. Oil type: see spare parts list. If the oil is dirty it has to be exchanged.
A. Upper oil plug
B. Lower oil plug
C. Stop screw / grease nipple
D. Inspection screw
The oil is drained by removing the plug, pos. B. In case of contaminated oil, check the seals and wear bushings.
Oil is filled by oil plug, pos. A.
Grease the front sealing system (see spare part list if necessary). Grease lubrication must be done by removing the
stop screw, pos. C, which sits just behind the propeller hub; enclosed grease nipple is fitted, after which grease
lubrication must take place through this. Before any reassembly of the propeller, fill the hub with grease.
The motor casing must be checked in the following way: Remove the inspection plug, pos. D beneath the motor. Any
leakage of oil or liquid can be seen immediately.
In case of abnormal leakage, it is necessary to check the seal in the oil chamber. In case of doubt, Landia can be
contacted. If it is necessary to dry up the motor windings, contact a special workshop.
Equipment
The equipment should be checked for wear and corrosion. The winch needs to be lubricated with grease. The brake
and lock must be checked. Tightening of screws must be done. If the screws are loose, remove them and lubricate
with an adhesive substance (e.g. Loctite) prior to reinstallation.
Disassembling/assembling
A major repair should take place at a special workshop.
Below please find some general conditions regarding disassembling/ assembling of Landia mixer type POPR-I.
The drawing attached to the spare parts list shows the construction of the unit. Not all parts can/should be removed,
e.g. do not press the rotor off the shaft.
When disassembling the unit, handle the mechanical seals with care as they are not shock resistant.
Prior to reinstallation, all sealing surfaces must be cleaned; all O-rings must be checked and changed if necessary.
Adhesive substance (e.g. Loctite) must be applied on all bolt joints. All bolts are tightened with a tightening torque
acc. to the table below.
Bolt sizes
Quality 10.9 - 12.9
Steel
Quality A4-80
Acidproof
M6
14 Nm
10 Nm
M8
34 Nm
24 Nm
M10
67 Nm
48 Nm
M12
115 Nm
82 Nm
M16
160 Nm
137 Nm
M20
200 Nm
180 Nm
M30
620 Nm
620 Nm
Summary of Contents for POP-1