Data Sheet
AC00B.C13
Page 4/5
landiaworld.com
Prepared by: BN
V/GB
Approved by: KSK/TM
Issued on: 1 January 2018
Rev. date: 3 January 2019
Motor type
3-phase AC motor
Nominal voltage
400 V
Minimum voltage allowed
360 V
Nominal frequency
50 Hz
Applicable for VFD operation
Yes
Ingress protection rating
IP 68
Insulation class
F
ATEX classificatio
Not possible
ELECTRICAL DATA
Model
Item number
Nominal power
Motor
Full load current
(400 V)
Connection
method
Start current
(DOL)
cos phi
Efficiency
[kW]
[rpm]
[A]
Y/∆
[A]
[%]
PODR-I 1.1 kW-1,000 rpm IE2
1236201
1.1
955
2.75
Y
15
0.71
78.1
PODR-I 4.0 kW-1,000 rpm IE2
1236204
4.0
965
8.5
Δ
43
0.79
85.5
PODR-I 7.5/5.5 kW-1,000 rpm IE2
1236207
7.5
970
15.5
Δ
91
0.79
87.5
For voltages others than 400 V/50 Hz please refer to the attached Appendix.