5. DISPENSER DISPOSAL
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was pur
chased. Comply with local regulations regarding disposal of the refrigerant and insulation.
TROUBLE
CAUSE
REMEDY
4.28 BIB pump fails to restart when
dispensing valve is closed.
A. Leak in discharge line or fittings.
B. Empty BIB.
C. Air leak on inlet line or bag connector.
A. Repair or replace discharge
B. Replace BIB.
C. Repair or replace.
4.29 No product out light.
A. Burned-out lamp
B. Faulty wiring or pressure switch in
product line.
A. Replace lamp.
B. Repair or replace.
4.30
Low or no carbonation.
A. Low or no CO
2
.
B. Excessive water pressure.
C.Worn or defective carbonator pump.
D.PCB malfunctioning.
A. Check CO
2
supply. Adjust CO
2
pressure to 70 PSI (0.483 MPA).
B. Water regulator should be set at 50
PSI (0.345 MPA)
C. Replace carbonator pump.
D. See Section 6.