Volumetric Valve Adjustment
The Volumetric Valve is an optional valve for the 44” Sensation dispenser
NOTE
VALVE SPECIFICATIONS
Finished Drink Flow Rates
3.0 oz/sec (88.7 ml/sec)
2.25 oz/sec (66.6 ml/sec)
1.5 oz/sec (44.4 ml /sec)
Flowing Pressure Requirements
MINIMUM
MAXIMUM
Water
40 psi (0.276 MPa)
110 psi (0.758 MPa)
Syrup
20 psi (0.138 MPa)
70 psi (0.483 MPa)
Electrical Requirements
24 VAC, 50/60 Hz
If the programmer does not run its diagnostic test
properly, disconnect it and try plugging it in again. If
the programmer still fails, replace the programmer
NOTE
- Handheld Programmer
Volumetric Valve
1.
Remove the ID panel from the front of the first valve.
2. Insert the programmer’s 10-pin connector into the ID panel
plug located on the front of the circuit board.
3. When properly connected, the programmer will run a self
diagnostic test. The display will show all “8’s” with the
decimal points lighted. After about three (3) seconds, the
display indicates the setting of the dip switches.
4. After the programmer is connected, Press the “Read Mem”
button.
5. Press the “Ratio +” or the “Ratio -” key until the desired ratio
is displayed.
6. Verify the drink type by pressing “Carb Toggle” to select “C”
for carbonated or “n” for non-carbonated.
7. Press the “Enter” button to program the valve with the
setting on the display.
8. Verify Ratio by pressing “Read Mem”.
9. Disconnect the programmer and repeat steps 4-9 for each
valve.