background image

8

Cleaning Solution

Mix a mild, non-abrasive detergent (e.g. Sodium Laureth 

Sulfate, dish soap) with clean, potable water at a temperature 

of 90°F to 110°F (32°C to 43°C). The mixture ratio is one ounce 

of cleaner to two gallons of water. Prepare a minimum of five 

gallons of cleaning solution. Do not use abrasive cleaners or 

solvents because they can cause permanent damage to the unit. 

Ensure rinsing is thorough, using clean, potable water at a  

temperature of 90°F to 110°F. Extended lengths of product lines 

may require additional cleaning solution.

Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF  

guidelines. The operator of the equipment must provide continuous maintenance as required by this manual and/or 

state and local health department guidelines to ensure proper operation and sanitation requirements are maintained.
The cleaning procedures provided herein pertain to the Lancer equipment identified by this manual. If other equipment 

is being cleaned, follow the guidelines established by the manufacturer for that equipment.
Cleaning should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning operations.           

Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

GENERAL INFORMATION

•  Use sanitary gloves when cleaning the unit and observe all applicable safety precautions.

•  DO NOT

 use a water jet to clean or sanitize the unit.

•  DO NOT

 disconnect water lines when cleaning and sanitizing syrup lines, to avoid contamination.

•  DO NOT

 use strong bleaches or detergents; These can discolor and corrode various materials.

•  DO NOT

 use metal scrapers, sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser.

•  DO NOT

 use hot water above 140° F (60° C). This can damage the dispenser.

•  DO NOT

 spill sanitizing solution on any circuit boards. Insure all sanitizing solution is removed from the system.

ATTENTION

CLEANING AND SANITIZING

Sanitizing Solution

 

Prepare the sanitizing solution in accordance with the  

manufacturer’s written recommendations and safety guidelines. 

The type and concentration of sanitizing agent recommended in 

the instructions by the manufacturer shall comply with 40 CFR 

§180.940. The solution must provide 100 parts per million (PPM) 

chlorine (e.g. Sodium Hypochlorite or bleach) and a minimum of 

five gallons of sanitizing solution should be prepared.

Scheduled Maintenance & Cleaning

As Needed

•  Keep exterior surfaces of dispenser (include drip tray and cup rest) clean using a clean, damp cloth.

Daily

• 

Remove each nozzle and diffuser and rinse well in warm water. 

DO NOT

 use soap or detergent. This 

will cause foaming and off taste in finished product.

•  Remove cup rest and wash in warm soapy water.
•  Pour warm soapy water into the drip tray and wipe with a clean cloth.
• 

With a clean cloth and warm water, wipe off all of the unit’s exterior surfaces. 

DO NOT USE  

ABRASIVE SOAPS OR STRONG DETERGENTS.

• 

Replace the cup rest, diffusers, and valve nozzles.

Weekly

• 

Taste each product for off tastes.

•  Remove the unit’s bonnet and check the level of water in the water bath. Replenish as required and 

replace bonnet. 

Monthly

•  Unplug the dispenser from the power source.
•  Remove the bonnet and clean the dirt from the gas cooler using a soft brush. 
•  Replace the bonnet and plug in the unit.

Summary of Contents for 9000 series

Page 1: ...sion 00 0 April 2020 The dispenser is for indoor use only This unit is not a toy Children should be supervised not to play with appliance It should not be used by children or infirm persons without su...

Page 2: ...it Do not plug into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each disp...

Page 3: ...the counter top the dispenser base must be sealed to the counter top with a bead of clear silicone caulk or sealant which provides a smooth and easily cleanable bond to the counter 3 Once the dispens...

Page 4: ...cm could cause the lines to freeze ATTENTION The water bath compartment must be filled with water before plugging in the unit otherwise the compressor fan may not operate properly DO NOT use RO or pu...

Page 5: ...is present in regulator attachment nut ATTENTION Installing CO2 Supply 1 Connect high pressure CO2 regulator assembly to CO2 cylinder or bulk system Thread regulator nut on to tank then tighten nut wi...

Page 6: ...Plug the Pump Motor Connector back into the control box A Regulator Adjustment Screw B Adjust to 75 psi 0 517 MPa C Wrench A B C 9 Turn power on 10 Activate each valve until a steady flow of carbonate...

Page 7: ...of the first valve 2 Insert the programmer s 10 pin connector into the ID panel plug located on the front of the circuit board 3 When properly connected the programmer will run a self diagnostic test...

Page 8: ...amination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives or solvents on the dispen...

Page 9: ...t until there is no aftertaste Do not use a fresh water rinse This is a NSF requirement Residual sanitizing solution left in the system creates a health hazard CAUTION Cleaning and Sanitizing Nozzles...

Page 10: ...yrup flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 psi 0 550 MPa minimum 70 psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form uppe...

Page 11: ...3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 8 High beverage temperature 1 Correct prior to dispenser Consider...

Page 12: ...ide com lancerworldwide com WIRING PLUMBING DIAGRAMS Plumbing Diagram PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S2 S1 S3 S4 S5 S6 PRESSURE SETTINGS CO 75 psi 50 psi WATER 2 PLA...

Reviews: