2

Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must 

be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches 

(9.525 mm) pipe with a minimum of 25 psi (0.172 MPa) line pressure, but not exceeding a maximum of 65 psi (0.448 MPa).  

Water pressure exceeding 65 psi (0.448 MPa) must be reduced to 65 psi (0.448 MPa) with the provided pressure regulator. Use 

a filter in the water line to avoid equipment damage and beverage off-taste. Check the water filter periodically, as required by local 

conditions. The water supply must be protected by means of an air gap, a backflow prevention device or another approved method 

to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to flow back through the pump when it 

is shut off and contaminate the water supply. Ensure the backflow prevention device complies with ASSE and local standards. It is 

the responsibility of the installer to ensure compliance.

!

Water Notice

SPECIFICATIONS

DIMENSIONS

Width

: 16.86 inches (429 mm)

Depth

: 25.56 inches (649 mm)

Height

: 26.86 inches (657 mm)

WEIGHT

Shipping

: 160 lbs (72.5 kg)

Empty

: 146 lbs (66.2 kg)

Operating

: 237 lbs (107.5 kg)

Ice Bath

: 22 - 24 lbs (10.0 - 10.9 kg)

CARBON DIOXIDE (CO

2

) SUPPLY

Min Pressure

: 70 psi (0.483 MPa)

Max Pressure

: 80 psi (0.552 MPa)

FITTINGS

Water for Carb Inlet

: 3/8 inch barb

Brand Syrup Inlets

: 1/4 inch barb

CO

2

 Inlet

: 3/8 inch barb

ELECTRICAL

115 VAC, 60 Hz, 8.0 Amps

220-240 VAC, 50/60 Hz, 4.0 Amps

PLAIN WATER SUPPLY

Min Flowing Pressure

: 25 psi (0.172 MPa)

Max Static Pressure

: 65 psi (0.448 MPa)

This unit emits a sound pressure level below 70 dB

Max Altitude: 16,400 ft (5,000 m)

Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 

electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with 

this unit. Do not ‘gang’ together with other electrical devices on the same outlet. 

Do not locate multiple portable socket-outlets or 

portable power supplies at the rear of the appliance. 

The key-switch does not disable the line voltage to the transformer primary. 

Always disconnect electrical power to the unit  to  prevent  personal injury before attempting any internal maintenance. The  

resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the 

unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all water lines are 

tight and units are dry before making any electrical connections!

Electrical Warning

WARNING:

 Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO

2

 may

displace oxygen in the blood.

WARNING: 

Prolonged exposure to CO

2

 can be harmful. Personnel exposed to high concentrations of CO

2

 gas will experience

tremors which are followed by a loss of consciousness and suffocation.

WARNING: 

If a CO

2

 gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.

WARNING: 

Strict attention must be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and soft drink system.

Carbon Dioxide (CO

2

)

Your Service Agent:

Service Agent Telephone Number: 

Serial Number:

Model Number:

This manual was developed by the Lancer 

Worldwide

 as a reference for the owner/operator and installer of this  dispenser. 

Please read this guide before installation and operation of this dispenser. If service is required please call your Lancer 

Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

Summary of Contents for 9000 series

Page 1: ...sion 00 0 April 2020 The dispenser is for indoor use only This unit is not a toy Children should be supervised not to play with appliance It should not be used by children or infirm persons without su...

Page 2: ...it Do not plug into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each disp...

Page 3: ...the counter top the dispenser base must be sealed to the counter top with a bead of clear silicone caulk or sealant which provides a smooth and easily cleanable bond to the counter 3 Once the dispens...

Page 4: ...cm could cause the lines to freeze ATTENTION The water bath compartment must be filled with water before plugging in the unit otherwise the compressor fan may not operate properly DO NOT use RO or pu...

Page 5: ...is present in regulator attachment nut ATTENTION Installing CO2 Supply 1 Connect high pressure CO2 regulator assembly to CO2 cylinder or bulk system Thread regulator nut on to tank then tighten nut wi...

Page 6: ...Plug the Pump Motor Connector back into the control box A Regulator Adjustment Screw B Adjust to 75 psi 0 517 MPa C Wrench A B C 9 Turn power on 10 Activate each valve until a steady flow of carbonate...

Page 7: ...of the first valve 2 Insert the programmer s 10 pin connector into the ID panel plug located on the front of the circuit board 3 When properly connected the programmer will run a self diagnostic test...

Page 8: ...amination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives or solvents on the dispen...

Page 9: ...t until there is no aftertaste Do not use a fresh water rinse This is a NSF requirement Residual sanitizing solution left in the system creates a health hazard CAUTION Cleaning and Sanitizing Nozzles...

Page 10: ...yrup flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 psi 0 550 MPa minimum 70 psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form uppe...

Page 11: ...3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 8 High beverage temperature 1 Correct prior to dispenser Consider...

Page 12: ...ide com lancerworldwide com WIRING PLUMBING DIAGRAMS Plumbing Diagram PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S2 S1 S3 S4 S5 S6 PRESSURE SETTINGS CO 75 psi 50 psi WATER 2 PLA...