WIRING/PLUMBING DIAGRAMS

Plumbing Diagram

PLAIN WATER

COILS

CARB.

HIGH PRESSURE

WATER PUMP

V6

V5

V4

V3

V2

V1

S2

S1

S3

S4

S5

S6

PRESSURE SETTINGS

CO

75 psi
50 psi

WATER

2

PLAIN WATER INLET

TO CARBONATOR

PLUMBING DIAGRAM

DELTA III 9000

®

Wiring Diagram

® 

Summary of Contents for 9000 series

Page 1: ...sion 00 0 April 2020 The dispenser is for indoor use only This unit is not a toy Children should be supervised not to play with appliance It should not be used by children or infirm persons without su...

Page 2: ...it Do not plug into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available Follow all local electrical codes when making connections Each disp...

Page 3: ...the counter top the dispenser base must be sealed to the counter top with a bead of clear silicone caulk or sealant which provides a smooth and easily cleanable bond to the counter 3 Once the dispens...

Page 4: ...cm could cause the lines to freeze ATTENTION The water bath compartment must be filled with water before plugging in the unit otherwise the compressor fan may not operate properly DO NOT use RO or pu...

Page 5: ...is present in regulator attachment nut ATTENTION Installing CO2 Supply 1 Connect high pressure CO2 regulator assembly to CO2 cylinder or bulk system Thread regulator nut on to tank then tighten nut wi...

Page 6: ...Plug the Pump Motor Connector back into the control box A Regulator Adjustment Screw B Adjust to 75 psi 0 517 MPa C Wrench A B C 9 Turn power on 10 Activate each valve until a steady flow of carbonate...

Page 7: ...of the first valve 2 Insert the programmer s 10 pin connector into the ID panel plug located on the front of the circuit board 3 When properly connected the programmer will run a self diagnostic test...

Page 8: ...amination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects steel wool scouring pads abrasives or solvents on the dispen...

Page 9: ...t until there is no aftertaste Do not use a fresh water rinse This is a NSF requirement Residual sanitizing solution left in the system creates a health hazard CAUTION Cleaning and Sanitizing Nozzles...

Page 10: ...yrup flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 psi 0 550 MPa minimum 70 psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form uppe...

Page 11: ...3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 8 High beverage temperature 1 Correct prior to dispenser Consider...

Page 12: ...ide com lancerworldwide com WIRING PLUMBING DIAGRAMS Plumbing Diagram PLAIN WATER COILS CARB HIGH PRESSURE WATER PUMP V6 V5 V4 V3 V2 V1 S2 S1 S3 S4 S5 S6 PRESSURE SETTINGS CO 75 psi 50 psi WATER 2 PLA...