1.6 CONNECTING PYTHON TO TOWER
12
5
WARNING
DO NOT TURN ON THE CO2 SUPPLY AT THIS TIME.
ADVERTENCIA
NO CONECTE TODAVÍA LA ALIMENTACIÓN DE CO2.
AVERTISSEMENT
N’OUVREZ PAS L’ALIMENTATION EN CO2 À CE MOMENT.
!
WARNING
USE A SHARP KNIFE, RAZOR BLADE, OR TUBE CUTTER TO CUT TUBING. TUBING CUT WITH A SAW
WILL RESULT IN PLASTIC SHAVINGS WHICH WILL PLUG THE FLOW CONTROLS IN THE DISPENSING VALVES.
ADVERTENCIA
UN CUCHILLO AFILADO, CUCHILLA DE AFEITAR, OR CORTATUBOS PARA CORTAR TUBO.
CORTE EL TUBO CON UNA SIERRA DARÁ LUGAR A LAS VIRUTAS DE PLÁSTICO QUE ENCHUFE LOS
CONTROLES DE FLUJO EN LAS VÁLVULAS DE DISTRIBUCIÓN.
AVERTISSEMENT
UTILISEZ UN COUTEAU SHARP, LAME DE RASOIR, OU TUBE CUTTER POUR COUPER DES
TUBES. COUPE TUBE AVEC UNE SCIE PROVOQUER DES COPEAUX EN PLASTIQUE QUI BRANCHEZ LES
CONTRÔLES DE FLUX DANS LES VANNES DE DISTRIBUTION.
A. Route opposite end of python to tower. Determine length required and cut if necessary. Be sure
to allow 12 inches (305 mm) of extra tubing length below the counter for servicing and moving
the unit.
B. Slit python insulation back 12 inches (305 mm) from end and roll insulation back to expose
individual tubes.
C. Connect each of the plastic lines from the python to the barbed fittings on each of the stainless
steel syrup, soda, and plain water (if used) lines on the tower manifold. Start with the
connections at the back of the tower manifold first. Secure with Oetiker clamps from kit.
NOTE:
Do not insulate connections at this time. Leave all connections exposed to inspect for leaks.
1.7 CONNECTING TO WATER SUPPLY
NOTE:
Adhere to the WATER SUPPLY Warnings/Cautions, Page 9.
A. Using proper beverage tubing and fittings, connect tubing assembly to water source.
B. Flush water supply line thoroughly.
NOTE:
Off tastes and excessive silt, sand, or iron require that a water filter be installed in the water
line supplying the carbonator. The water filter should be checked periodically, as required by local
conditions. Do not connect to a heated (hot) water source or a water source supplying soft
water. This will cause excessive foaming.
C. Attach water supply to recirculation unit using a flare seal washer. Leave an additional
12 inches (305 mm) of extra tubing for servicing and moving unit.
D. Turn on water supply.
E. Vent air from the system by lifting the yellow lever on the relief valve on the carbonator tank until
water comes out.
F. Operate each of the dispensing faucets until a good flow of water is established and all of the
air is removed from the lines.
G. Check all water and soda line connections for leaks.
H. Using test gauge assembly (PN 22-0138), set regulator (if installed) at 50 PSIG (0.345 MPA).
1.8 CONNECTING THE CO2 SUPPLY
NOTE:
Adhere to the CARBON DIOXIDE Warnings/Cautions, Page 8.
A. Connect the high pressure CO2 regulator assembly to CO2 cylinder. Use a new CO2 tank
washer if regulator does not have built-in o-ring seal.
B. Place CO2 cylinder in service location and secure it with a safety chain.
C. Using tubing and fittings from installation kit connect tubing assembly to CO2 regulator using
flare seal washer (PN 05-0011). Use a back-up open end wrench to prevent damage to
regulator assembly.
D. Attach tubing to recirculating unit using back-up open end wrench on fitting. Leave an additional
12 inches (305 mm) of extra tubing for servicing and moving the unit.