background image

 

7.2   2500 REFRIGERATION DECK ASSEMBLY, R-134A, LANCER ELECTRONIC ICE BANK

 

 

CONTROL (EIBC), USA ONLY, PN 82-2669 (CONTINUED)

 

 

(MANUFACTURED FROM 01/99)

Item  Part No. 

Description

R  1   23-0986  

Condenser

R  2   51-0349  

Shroud Assy

R  3   25-0047  

Transformer, 115V/60Hz

R  4   83-0101  

Compressor, 115V/60Hz

R  4A   12-0233  

Start Capacitor, 115V/60Hz

R  4B   12-0227  

Overload, 115V/60 Hz

R  4C   12-0232  

Relay, 115V/60Hz

R  -  

- - - - - - -  

Refrigerant, R134A Only,

   

 

15.5 Ounces

R  5   23-1205  

Evaporator Coil Assy

R  6   82-0675  

Compressor Deck Assy

R  7   04-0032  

Nut, 1/4 - 20

R  8   04-0063  

Washer, 0.260 ID x 0.687  

 

OD, SS

R  9   07-0268  

Deck Handle

R  10   04-0260  

Screw, 10 - 16 x 0.625

R  11   04-0538  

Fill Hole Plug

R  12   02-0114  

Grommet, Compressor

R  13   04-0537  

Washer, Compressor

R  14   03-0150  

Retainer Clip, Compressor

R  15   23-0999  

Dryer/Capillary Tube Assy

R  16   51-5400  

Accumulator

R  17   04-0504  

Screw, 8 -18 x 0.375

R  18   47-2064  

Tube, High Side

R  19   50-0105  

Accumulator Insulator Boot

R  20   50-0106  

Insulation, Low Side

R  21   50-0107  

Insulation, Evaporator Outlet

R  22   50-0108  

Insulation, Evaporator Inlet

R  23   52-1882  

Electronic Ice Bank Control

    

(EIBC)

R  24   03-0049  

Cord Clip

R  25   52-0100  

Power, Junction Assy

R  26   06-0031/01  

Wiring Diagram, 2500

R  27   52-1259  

Agitator Motor Assy,  

 

 115V/60Hz

R  27A  91-0083  

Motor, Agitator, 115V/60Hz

R  27B  05-0502  

Propeller, Agitator

R  27C  02-0032  

Washer, Rubber, 1.000 OD

R  27D  30-5113/01  

Agitator Motor Bracket

R  27E  04-0059  

Screw, 8 - 36 x 0.375

R  27F  05-0424/01  

Agitator Fan

R  27G  06-0633  

Label, 115V/60Hz, 25W

R  28   52-0740  

Fan Motor Assy, 115V/60Hz

R  28A  91-0017  

Fan Motor, 115V/60Hz

R  28B  07-0257  

Fan Blade

R  28C  30-0043  

Bracket, Fan Motor

R  28D  04-0059  

Screw, 8 - 36 x 0.375

R  28E  04-0060  

Nut, Fan Blade

R  28F  02-0413  

Silencer, Fan Blade

R  28G  06-0667  

Label, 115V/60Hz, 35W

R  29   11-0118  

Connector, Ground

R  30   47-2033/01  

Tube, Suction

R  31   47-0344  

Tube, Process

R  32   04-0070  

Screw, 10 - 24 x 1.312

Item  Part No. 

Description

R  33   01-1713  

Reducer, Fitting, Elbow

R  34   52-0878  

Wire, Transformer Lead,  

 Primary

R  35   52-0879  

Wire, Transformer Lead,  

 Primary

R  36   06-0856/01  

Fill Hole Label

R  37   02-0040  

Seal, Extrusion

R  38   06-0663  

Label, 115V/60Hz, 3/4 HP

R  39   21-0085  

Power Cord, USA

R  40   52-1504  

Wire Assy, Secondary, White

R  41   52-1505  

Wire Assy, Secondary, Black

R  42   02-0041  

Seal

R  43   52-1897  

Probe Assy

R  44   04-0394  

Screw, 6 - 32 x 0.500, PHP,  

 SS

R  45   52-1827  

Harness Assy, EIBC

R  46   13-0059  

Bushing, Heyco

R in margin indicates change or revision 

23

Summary of Contents for 2500 REMOTE series

Page 1: ...arranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0377 03 JANUARY 1999 FOR QUALIFIED INSTALLER ONLY Lancer is the registered trademark of Lancer 2014 by Lancer all rights reserv...

Page 2: ...REMOTE RECIRCULATING UNIT 10 1 4 CONNECTING TO ELECTRICAL POWER 11 1 5 CONNECTING PYTHON TO RECIRCULATING UNIT 11 1 6 CONNECTING PYTHON TOWER 12 1 7 CONNECTING TO WATER SUPPLY 12 1 8 CONNECTING TO CO...

Page 3: ...4 12 WATER IS RELEASED FROM PRESSURE RELIEF VALVE 18 4 13 LOW CARBONATION 18 4 14 FOAMY PRODUCT 18 5 BASIC GO NO GO CARBONATOR CONTROL TEST 19 6 DISPENSER DISPOSAL 19 7 ILLUSTRATIONS PARTS LISTINGS A...

Page 4: ...AL 230 240VAC 50 60Hz 2 6AMPs WEIGHT Ice Bank 50 55 lbs 23 25 kg Operating 457 lbs 207 30 kg Shipping 340 lbs 154 22 kg WATER BATH Capacity 21 gallons 79 liters FITTINGS Water for carbonator inlet 3 8...

Page 5: ...Clamps Fittings Water Booster Water Regulator Precision Cutters if removing replacing carbonator tank CONSIDER LOCATION OF THE FOLLOWING PRIOR TO INSTALL Water supply lines Drain Is the countertop lev...

Page 6: ...supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere la unidad por...

Page 7: ...izador de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la cor...

Page 8: ...iques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres ap...

Page 9: ...d local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo men...

Page 10: ...ay not operate properly and the dispenser will freeze up Locate dispenser to allow approximately 15 inches 380 mm of unobstructed space above and six 6 inches 152 mm of unobstructed space in back of t...

Page 11: ...nsulate connections at this time Leave all connections exposed to inspect for leaks F GROUNDING WARNING THE DISPENSER MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID SERI OUS INJURY OR FATAL ELECTRICA...

Page 12: ...e to the WATER SUPPLY Warnings Cautions Page 9 A Using proper beverage tubing and fittings connect tubing assembly to water source B Flush water supply line thoroughly NOTE Off tastes and excessive si...

Page 13: ...0 414 MPA MAIS NON INF RIEUR E Continue to purge air from the syrup and soda lines until all air has been removed and only soda and syrup are flowing steadily from the valve Repeat this procedure for...

Page 14: ...in warm water DO NOT use soap or detergent This will cause foaming and off taste in finished product B Remove the cup rest and wash in warm soapy water C Pour warm soapy water into the drip tray and...

Page 15: ...manufacturer s recommendations Make sure the lines are completely filled and allow to stand for at least ten 10 minutes C Flush the detergent solution from the lines with clean water D Prepare the Sa...

Page 16: ...starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure D Replace compressor 4 4 Compressor starts but does not switch off start winding will run for on...

Page 17: ...water supply C Refrigeration system not running D Refrigeration leak E Condenser fan motor not working F Dirty Condenser G Dispenser capacity exceeded A Check clearances around sides top and inlet of...

Page 18: ...nd clean E Remove and clean Pump Strainer If Pump is still restricted replace Pump F Replace PC Board G Replace Probe 4 12 Water is released from Pressure Relief Valve A Defective seal in Pressure Rel...

Page 19: ...minals The motor should continue to run If the motor does not continue to run the board is bad If motor runs go to step 6 6 Connect the remaining clip to the Hl terminal The motor should stop If the m...

Page 20: ...AGRAMS 7 1 REMOTE BEVERAGE SYSTEM ASSEMBLY 37 36 34 33 16B 16A 16 39 32 19B 19C 19 19A 41 3 31 29 28 15 SEE VIEW A 11 24 23 2 9 14 5 8 26 27 30 37 12 18A 17 35 40 38 25 13 10 VIEW A 22 18B 24 7 20 1 2...

Page 21: ...r Recirculating Deck Assy 115V 85 1928 01 Carbonator Recirculating Deck Assy 220V 19A 04 0035 Isolator 1 4 20 Double Stud 19B 04 0247 Isolator 1 4 20 Single Stud 19C 04 0032 Nut Lock 1 4 20 20 01 1060...

Page 22: ...26 28E 28B 28F 28A 28C 42 28D 22 38 19 16 28 34 35 30 20 40 41 3 17 17 29 37 7 8 43 44 5 24 9 10 6 WA TER BAT H FILL HO LE IMP OR TAN T FILL WA TER BAT H UNT IL WA TER FLO WS FRO M TAN K OVE RFL OW TU...

Page 23: ...ord Clip R 25 52 0100 Power Junction Assy R 26 06 0031 01 Wiring Diagram 2500 R 27 52 1259 Agitator Motor Assy 115V 60Hz R 27A 91 0083 Motor Agitator 115V 60Hz R 27B 05 0502 Propeller Agitator R 27C 0...

Page 24: ...240V 60Hz INTERNATIONAL ONLY 24 WA TE R BAT H FIL L HO LE IM PO RTA NT FIL L WA TE R BAT H UN TIL TAN K OV ER FLO W TU BE WA TE R FLO WS FR OM 1 18 31 2 28D 17 22 28E 28B 28F 28A 17 21 28C 16 19 30 2...

Page 25: ...0 0107 Insulation Evaporator Outlet R 22 50 0108 Insulation Evaporator Inlet R 23 52 2026 Control Housing Assy EIBC R 24 03 0049 Cord Clip R 25 52 1773 Probe Assy EIBC R 26 04 0394 Screw 6 32 x 0 500...

Page 26: ...CARB S1 S6 S5 S4 S3 S2 SODA OUT WATER OUT SODA RECIRC S1 S2 S3 S4 S5 S6 THERMO SODA W SODA S1 W S2 S3 S4 S5 S6 S6 S5 S4 S3 S2 S1 REFRIGERATION UNIT WATER IN CO2 IN OUT IN SYRUP OUT WATER IN RECIRC PUM...

Page 27: ...27 WHITE 18 AWG COMP DECK OUTLET POWER CORD GND WHITE 18 AWG CARB OUTLET WHITE 18 AWG RECIRC OUTLET WHITE 18 AWG ON LIGHT RECIRC SWITCH WHITE 18 AWG CARB SWITCH BLACK 18 AWG 7 5 WIRING DIAGRAM...

Page 28: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: