background image

 

1.9   CONNECTING THE SYRUP SUPPLY

 

 

A.  Using proper beverage tubing and fittings, connect to syrup inlets at control panel.

 

 

B.  Mark syrup tube assemblies with product ID tape.

 

 

C.  Connect to appropriate syrup pumps.

 

1.10   PURGING AIR FROM THE SYSTEM

 

 

A.  Turn the CO2 supply on slowly. Set CO2 pressure at 40 PSI (0.276 MPA).

 

 

B.  Turn on carbonator pump motor at control panel.

  

NOTE:

 The carbonator pump should start operating when power is restored; however, the 

 

 

refrigeration system will not restart for five (5) minutes (EIBC units only).

 

 

C.  Purge air from the syrup lines by actuating each dispensing valve to quiet the syrup pumps.

 

 

D.  Adjust CO2 pressure upward to 70 PSI (0.483 MPA).

13

!

WARNING

 UNDER NO CIRCUMSTANCE SHOULD THE CO2 PRESSURE EXCEED 80 PSI (0.552 MPA).

PRESSURE ABOVE THIS LIMIT WILL RESULT IN DAMAGE TO THE SYRUP PUMPS. SHOULD REMOTE SYRUP 

PUMPS FAIL TO OPERATE PROPERLY AT 70 PSI (0.483 MPA), THE CO2 PRESSURE MAY BE REDUCED TO A 

MINIMUM PRESSURE OF 60 PSI (0.414 MPA), BUT NO LOWER.

ADVERTENCIA

 BAJO NINGUNA CIRCUNSTANCIA DEBE SUPERAR LA PRESIÓN DE CO2 80 PSI (0.552 MPA). 

PRESIÓN ENCIMA DE ESTE LÍMITE PUEDE CAUSAR DAÑOS A LAS BOMBAS DE JARABE. DEBE BOMBAS DE 

JARABE REMOTO IMPIDIENDO SU CORRECTO FUNCIONAMIENTO A 70 PSI (0.483 MPA), EL CO2 

LA PRESIÓN PUEDE SER REDUCIDA A UNA PRESIÓN MÍNIMA DE 60 PSI (0.414 MPA), PERO NO INFERIOR.

AVERTISSEMENT

 EN AUCUN CAS SI LA PRESSION DE CO2 DÉPASSENT 80 PSI (0.552 MPA). 

PRESSION DESSUS DE CETTE LIMITE ENTRAÎNERA DES DOMMAGES À LA POMPE DE SIROP. DEVRAIT 

POMPES DE SIROP DE DISTANCE EMPÊCHER DE FONCTIONNER NORMALEMENT AT 70 PSI (0.483 MPA), LE 

CO2 LA PRESSION PEUT ÊTRE RÉDUITE À UNE PRESSION DE MINIMUM DE 60 PSI (0.414 MPA), MAIS NON 

INFÉRIEUR.

 

 

E.  Continue to purge air from the syrup and soda lines until all air has been removed and only soda

 

 

  and syrup are flowing steadily from the valve. Repeat this procedure for each valve.

 

 

F.  Turn on recirculating pump motor at control panel.

  

NOTE:

 The recirculating pump should start operating when power is restored; however, the

 

 

refrigeration system will not restart for five (5) minutes (EIBC units only).

 

1.11   COMPLETE INSULATION BETWEEN REMOTE UNIT AND PYTHON

 

 

A.  Check all of the unit’s syrup, water and CO2 connections for leaks and repair if necessary.

 

 

B.  Close the python insulation which had been rolled back earlier for connection to remote unit

 

 

  syrup, soda and plain water (if used) lines. Seal python insulation to remote lines with plastic

 

 

  tape. There should be no gaps in the insulation.

!

CAUTION

 THE PYTHON INSULATION MUST BE AIR TIGHT TO PREVENT THE FORMATION OF CONDENSATION. 

ALL AREAS MUST BE SEALED WITH PLASTIC TAPE AND THEN COVERED WITH INSULATION TAPE. FAILURE TO 

SEAL BOTH ENDS OF PYTHON WILL RESULT IN POOR PERFORMANCE FROM DISPENSER.

PRECAUCIÓN

 EL AISLAMIENTO PYTHON, DEBERÁ SER ESTANCO AIRE PARA EVITAR LA FORMACIÓN DE 

CONDENSACIÓN. TODAS LAS ÁREAS DEBEN SELLARSE CON CINTA DE PLÁSTICO Y LUEGO SE CUBRE 

CON CINTA AISLANTE. NO SELLAR AMBOS EXTREMOS DE PYTHON QUE PUEDE REDUCIRSE EL 

RENDIMIENTO DE DISTRIBUIDOR.

ATTENTION

 L’ISOLATION DOIT ÊTRE ÉTANCHE PYTHON AIR POUR ÉVITER LA FORMATION DES 

CONDENSATION. TOUS LES DOMAINES DOIVENT ÊTRE SCELLÉS AVEC DU RUBAN ADHÉSIF, PUIS 

RECOUVERTE AVEC ISOLATION TAPE. NON SEAL DEUX EXTRÉMITÉS DE PYTHON DONNERA UNE MAUVAISE 

PERFORMANCE DE DISTRIBUTEUR.

 

 

C.  Starting as close to the remote unit as possible, wrap the syrup, soda and plain water (if used)  

  lines with a single layer of insulated tape until all plastic tape has been covered.

 

 

D.  Replace bonnet on remote unit.

Summary of Contents for 2500 REMOTE series

Page 1: ...arranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0377 03 JANUARY 1999 FOR QUALIFIED INSTALLER ONLY Lancer is the registered trademark of Lancer 2014 by Lancer all rights reserv...

Page 2: ...REMOTE RECIRCULATING UNIT 10 1 4 CONNECTING TO ELECTRICAL POWER 11 1 5 CONNECTING PYTHON TO RECIRCULATING UNIT 11 1 6 CONNECTING PYTHON TOWER 12 1 7 CONNECTING TO WATER SUPPLY 12 1 8 CONNECTING TO CO...

Page 3: ...4 12 WATER IS RELEASED FROM PRESSURE RELIEF VALVE 18 4 13 LOW CARBONATION 18 4 14 FOAMY PRODUCT 18 5 BASIC GO NO GO CARBONATOR CONTROL TEST 19 6 DISPENSER DISPOSAL 19 7 ILLUSTRATIONS PARTS LISTINGS A...

Page 4: ...AL 230 240VAC 50 60Hz 2 6AMPs WEIGHT Ice Bank 50 55 lbs 23 25 kg Operating 457 lbs 207 30 kg Shipping 340 lbs 154 22 kg WATER BATH Capacity 21 gallons 79 liters FITTINGS Water for carbonator inlet 3 8...

Page 5: ...Clamps Fittings Water Booster Water Regulator Precision Cutters if removing replacing carbonator tank CONSIDER LOCATION OF THE FOLLOWING PRIOR TO INSTALL Water supply lines Drain Is the countertop lev...

Page 6: ...supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere la unidad por...

Page 7: ...izador de corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la cor...

Page 8: ...iques locaux lorsque vous faites des connexions Chaque distributrice doit avoir un circuit lectrique s par N utilisez pas de cordons prolongateurs avec cet appareil Ne pas le brancher avec d autres ap...

Page 9: ...d local standards It is the responsibility of the installer to ensure compliance Proporcione un suministro adecuado de agua potable La l nea de suministro de agua debe ser de una tuber a de por lo men...

Page 10: ...ay not operate properly and the dispenser will freeze up Locate dispenser to allow approximately 15 inches 380 mm of unobstructed space above and six 6 inches 152 mm of unobstructed space in back of t...

Page 11: ...nsulate connections at this time Leave all connections exposed to inspect for leaks F GROUNDING WARNING THE DISPENSER MUST BE PROPERLY ELECTRICALLY GROUNDED TO AVOID SERI OUS INJURY OR FATAL ELECTRICA...

Page 12: ...e to the WATER SUPPLY Warnings Cautions Page 9 A Using proper beverage tubing and fittings connect tubing assembly to water source B Flush water supply line thoroughly NOTE Off tastes and excessive si...

Page 13: ...0 414 MPA MAIS NON INF RIEUR E Continue to purge air from the syrup and soda lines until all air has been removed and only soda and syrup are flowing steadily from the valve Repeat this procedure for...

Page 14: ...in warm water DO NOT use soap or detergent This will cause foaming and off taste in finished product B Remove the cup rest and wash in warm soapy water C Pour warm soapy water into the drip tray and...

Page 15: ...manufacturer s recommendations Make sure the lines are completely filled and allow to stand for at least ten 10 minutes C Flush the detergent solution from the lines with clean water D Prepare the Sa...

Page 16: ...starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure D Replace compressor 4 4 Compressor starts but does not switch off start winding will run for on...

Page 17: ...water supply C Refrigeration system not running D Refrigeration leak E Condenser fan motor not working F Dirty Condenser G Dispenser capacity exceeded A Check clearances around sides top and inlet of...

Page 18: ...nd clean E Remove and clean Pump Strainer If Pump is still restricted replace Pump F Replace PC Board G Replace Probe 4 12 Water is released from Pressure Relief Valve A Defective seal in Pressure Rel...

Page 19: ...minals The motor should continue to run If the motor does not continue to run the board is bad If motor runs go to step 6 6 Connect the remaining clip to the Hl terminal The motor should stop If the m...

Page 20: ...AGRAMS 7 1 REMOTE BEVERAGE SYSTEM ASSEMBLY 37 36 34 33 16B 16A 16 39 32 19B 19C 19 19A 41 3 31 29 28 15 SEE VIEW A 11 24 23 2 9 14 5 8 26 27 30 37 12 18A 17 35 40 38 25 13 10 VIEW A 22 18B 24 7 20 1 2...

Page 21: ...r Recirculating Deck Assy 115V 85 1928 01 Carbonator Recirculating Deck Assy 220V 19A 04 0035 Isolator 1 4 20 Double Stud 19B 04 0247 Isolator 1 4 20 Single Stud 19C 04 0032 Nut Lock 1 4 20 20 01 1060...

Page 22: ...26 28E 28B 28F 28A 28C 42 28D 22 38 19 16 28 34 35 30 20 40 41 3 17 17 29 37 7 8 43 44 5 24 9 10 6 WA TER BAT H FILL HO LE IMP OR TAN T FILL WA TER BAT H UNT IL WA TER FLO WS FRO M TAN K OVE RFL OW TU...

Page 23: ...ord Clip R 25 52 0100 Power Junction Assy R 26 06 0031 01 Wiring Diagram 2500 R 27 52 1259 Agitator Motor Assy 115V 60Hz R 27A 91 0083 Motor Agitator 115V 60Hz R 27B 05 0502 Propeller Agitator R 27C 0...

Page 24: ...240V 60Hz INTERNATIONAL ONLY 24 WA TE R BAT H FIL L HO LE IM PO RTA NT FIL L WA TE R BAT H UN TIL TAN K OV ER FLO W TU BE WA TE R FLO WS FR OM 1 18 31 2 28D 17 22 28E 28B 28F 28A 17 21 28C 16 19 30 2...

Page 25: ...0 0107 Insulation Evaporator Outlet R 22 50 0108 Insulation Evaporator Inlet R 23 52 2026 Control Housing Assy EIBC R 24 03 0049 Cord Clip R 25 52 1773 Probe Assy EIBC R 26 04 0394 Screw 6 32 x 0 500...

Page 26: ...CARB S1 S6 S5 S4 S3 S2 SODA OUT WATER OUT SODA RECIRC S1 S2 S3 S4 S5 S6 THERMO SODA W SODA S1 W S2 S3 S4 S5 S6 S6 S5 S4 S3 S2 S1 REFRIGERATION UNIT WATER IN CO2 IN OUT IN SYRUP OUT WATER IN RECIRC PUM...

Page 27: ...27 WHITE 18 AWG COMP DECK OUTLET POWER CORD GND WHITE 18 AWG CARB OUTLET WHITE 18 AWG RECIRC OUTLET WHITE 18 AWG ON LIGHT RECIRC SWITCH WHITE 18 AWG CARB SWITCH BLACK 18 AWG 7 5 WIRING DIAGRAM...

Page 28: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: