![background image](http://html2.mh-extra.com/html/lancer/2300-series/2300-series_installation-manual_3474445003.webp)
3
Dispenser Installation
The dispenser should only be installed in a location
where it can be overseen by trained personnel
NOTE
1. Select a level, well ventilated location that is in close
proximity to a properly grounded electrical outlet, within
five (5) feet (1.5 m) of a drain, a water supply that meets
the requirements shown in the Specifications section found
on pages 4-6, and away from direct sunlight or overhead
lighting
2. The selected location should be able to support the weight
of the dispenser and ice after the counter cut out is made.
Total weight (with ice) for this unit could exceed 400 pounds
(181.4 kg).
3. If installed directly on the counter, unit must be sealed to the
counter-top with an FDA approved sealant.
4. If installed using the free-standing conversion kit (Lancer PN:
84-0058), unit must use the legs provided.
5. Select a location for the remote carbonator, syrup pumps,
CO
2
tank, syrup containers, and water filter (recommended).
NSF listed units must be sealed to the counter or use
legs provided.
NOTE
Selecting Counter Location
The installation, and relocation if necessary, must
be carried out by qualified personnel with up-to-date
knowledge and practical experience, in accordance with
current regulations.
NOTE
1. Inspect the location where the unit is to be installed and if
necessary make counter cut-out, (See
Specifications
section
on page 2 or Cut-out Diagrams on page 11 for counter cut-
out dimensions).
Counter cut-out must be accurate, according to unit
specifications.
!
ATTENTION
2. Once the counter cut-out is made, lower the unit into the
counter and seal the rim to the counter using an approved
silicone sealant.
3. If using freestanding conversion kit, install per kit instructions
then insert and seal unit to freestanding frame. Position
freestanding unit in designated location.
4. Route appropriate tubing from the water source to the soda
water inlets at the front of the unit.
5.
Install tee fitting to water line split water line between the left
and right side soda water inlets.
6.
Install “U” fitting to each soda water line to complete soda
water line manifold.
A
B
C
A. “U” Fitting
B. Line to Tee Fitting
C. Line to Soda/Water Inlet
A
B
D
C
A. Tee Fitting
B. Line to Water Source
C. Line to Left Soda Inlets