Maintenance
6
Maintenance
6.1
Maintenance Tasks
NOTICE
The F130l evaluation device is maintenance-free.
However, you should at intervals – that depend on the operating conditions of the plant – clean
the aperture of the flame sensor and the associated viewing opening on the furnace.
NOTICE
The service life of the flame sensor is limited.
Refer to the manufacturer's specifications for the respective service life of the flame sensor.
An operation of the flame monitor outside of its specification is not permitted. Replace faulty
or aged flame sensors with new ones of the same type.
Observe the following general information:
•
The isolation of the ionisation electrode is subject to a contamination and the electrode a
loss of contact material. Clean the ionisation sensor at regular intervals and check for an
unpermitted loss of contact material (burn-up).
•
The optical sensors age and are subject in part to high environmental influences. There-
fore, clean the sensors at regular intervals and check for proper functioning.
Perform the following activities to the system during
regularly scheduled maintenance
:
•
Check of all electrical plug connections.
•
Place burner into operation.
•
Check flame monitor for proper function.
•
Check reaction time for flame failure (switch-off test) analogue to commissioning.
►
Is there a correct switch-off within the safety time parameterized according to chapter
•
Create a log for the measurements and tests that have been performed.
This must also be confirmed by signature of the operator, if necessary.
6.2
Customer Service Information
Please contact LAMTEC Service/Support if you have any questions.