8
SHIPPING
The burner is shipped fully assembled and packed in a single piece with the electric cables already
fitted.
We recommend you unpack the burner just before installation on the boiler in order to prevent that
accidental knocking damages it.
OIL POWERED
GAS POWERED
Min. – Max. capacity
kW
80,7 ÷ 63,8
80,7 ÷ 63,4
kcal/h x 0
3
69,4 ÷ 40,8
69,4 ÷ 40,5
Fuel consumption
kg/h- m
3
n
6,8 ÷ 3,8
8, ÷ 6,4
Fuel
Diesel oil PCI 0.0
kcal/kg ,3°E-0°C
Natural gas PCI 8570
kcal/m
3
n
Flexible hoses
¼“ - length 800 mm
Self-suction fuel pump with incorporated
electrovalve
calibration pressure kg/cm
MIN-MAX gas pressure
mbar
- 3
Electrical power supply
30 V - 50Hz
Electric motor – 860 rpm
W
70 ÷ 85
Condenser
µF
6,3
Ignition transformer
kV
0
mA
30
Flame control device
UV photocell
Air adjustment
Manual
Gas connector diameter
3/4” Gas
No. of stages
Weight
kg
8
Packing dimensions
mm
745 x 45 x 345
All types provided that 60° FULL CONE
,75 ÷ 3,50
TECHNICAL CHARATERISTICS