5.9 Dioptre setting
The dioptre setting
(2)
is located on the left-hand ocular
(1)
. In the normal position, the lower part of the sleeve
is aligned with the marking on the ocular tube. In the event of differing vision in both eyes: Open the right eye
only, look into the right-hand ocular and adjust the focus using the focusing screw
(4)
. Now look through
the left-hand ocular with your left eye and adjust the focus by turning the dioptre setting
(2)
until the image
appears focused.
6. Setup process
6.1 Description of the device front
6.2 Switching the device on
First, carefully open the gas canister valve. Then switch the mains master switch on the rear of the housing
to the “I” position. After switching on the device, the display shows the precautionary safety instructions,
in particular regarding eye protection and reading the operating manual carefully. The start menu is opened
by pressing the multifunctional controller once or pressing on the display.
6.3 Setting the correct gas volume
Please consider that good welding results can only be achieved with a correctly
adjusted gas flow! It may be necessary to adjust the gas flow.
In order to configure the correct gas volume, activate the gas valve in the settings menu. This opens
the gas valve in the welding device. Now set the flow regulator to the correct flow rate of approx. 2-3 litres/
min. When doing so, also observe the instructions provided with the flow regulator. Once the gas volume
is correctly adjusted, close the gas valve again by pressing the corresponding button.
(1)
Touch display
(2)
Multifunctional controller
(3)
Connection socket for contact elements
(4)
Connection socket for hand piece
(5)
Connection socket for fixation welding
16