3.
Check that the machine is clear of all tools and other loose objects.
4.
Check that all the adjusting and locking handles are tight.
5.
Check that there is no blade fitted; it is far safer to test the machine without a
blade fitted.
6
.
Start the bandsaw by pulling the red start/stop button out.
7.
The lower flywheel is now turning.
8.
Now is the time to check that the safety switch is functioning correctly before you
fit a blade. Never complete the following tests with a blade fitted, as it could cause
injury.
9.
With the machine running (no blade fitted), operate the red stop/start switch by
pressing toward the machine. The motor should have the power removed and
slowed down.
10.
If the switches fail to operate correctly, do not use the machine until the fault has
been corrected.
11.
Remove the Safety Plug from the switch whenever the tool is turned “OFF” and keep
Safety Plug out of the reach of unauthorized person or children.
Should the bandsaw fail the test, it must not be used until the fault has been
rectified.
The motor comes prewired 110V but can be reconfigured for 220V. If you
decide to reconfigure the motor to 220V, it must be rewired by a qualified
electrician. It must be noted that if the bandsaw is rewired for 220V, the 110V
plug at the back of the bandsaw must be disconnected. The plug that is
supplied with the machine will have to be changed to suit your power supply.
220V wiring drawing
Summary of Contents for 14-Twelve Bandsaw
Page 53: ...53 Electrical Drawing...
Page 54: ...54 Industrial Work Light Optional Exploded View Drawings and Parts List...
Page 55: ...55 Lower Wheel And Motor Assembly...
Page 56: ...56 Stand Assembly...
Page 57: ...57 Table and Fence Assembly...
Page 58: ...58 Upper and Lower Blade Guides Assembly...
Page 59: ...59 Upper Wheel Assembly...
Page 60: ...60 Wheel System Optional...