SmartShop|Maker Owner’s Manual
63
Error Code
Potential Issue(s)
Resolution(s)
Repeat count, L, should be
integer
Programming error
Please check the program and
use the repetitive times L in
integer.
Incompatible data type
Machining program is not
compatible with the Syntec
controller
Verify the date format is suitable
for controller.
Tool length number, H, over
range
Programming error
Verify the tool length number, H,
is in the range of tool number.
G10 table index, P, over
range
Program error
Use reasonable value P in G01
table index.
Tool radius number, D, over
range
Program error
Verify the tool radius number D
is in range of the tool number.
Tool nose number over range Program error
Verify the tool radius number D
is in the range of tool number.
Subprogram call sequence
num., H, must integer
Program error
Change the number H of
subprogram into an integer.
M99 return sequence
number, P, must integer
Program error
Change the return sequence
number P of M99 into an
integer.
Workpiece number over
range
Program error
Verify the number of work
pieces in the allowed range of
the controller.
Dwell skip source, Q, must be
integer
Program error
Change the dwell skip source Q
into an integer.
Dwell skip source Q, over
range
Program error
Verify the dwell skip source Q in
the allowed range.
Summary of Contents for SmartShop Maker
Page 1: ...SmartShop Maker Owner s Manual Laguna Tools 744 Refuge Way Grand Prairie TX lagunatools com...
Page 6: ...SmartShop Maker Owner s Manual 6 NOTES...
Page 12: ...SmartShop Maker Owner s Manual 12 NOTES...
Page 38: ...SmartShop Maker Owner s Manual 38 NOTES...
Page 66: ...SmartShop Maker Owner s Manual 66 NOTES...
Page 69: ...SmartShop Maker Owner s Manual 69 Laguna Tools Warranty...