Error Code
Potential Issue(s)
Resolution(s)
CF card set by Pr3219 is
error, check CF card or
system setting value
1. The system doesn’t have the
2
nd
CF or cannot read the 2
nd
CF card.
2. The system has two (2) CF
cards, but only one CF card is
partition.
1. Check whether the 2
nd
CF
card exists or there is CF
card reading error.
2. Set the first card to the
default state, have two (2)
partition states.
3. Set parameters 3219 equal
to 0 to use C: all.
Software version and model
can’t driver hardware, call
your vender
1. The hardware doesn’t support
software version set on the
controller, ex: EZ milling setups
10.114 software version.
2. In the controller, the
motherboard, or IO card and
CF card are replaced and
software version doesn’t
support new hardware.
1. Install the software version
that supports the machine
model, ex: EZ type uses
9.242 software version. Or
open the option, ex:
option1 “EZ2/3/4 upgrade
10A software function”.
2. Ask Syntec for the
password to solve the
incompatible hardware
problem.
3. Super Controller doesn’t
have this error.
WinCE option not enabled,
call your vender
The Option 2 of controller
“Controller upgrades WindCE
system” is not opened.
1. Install DOS version.
2. Ask Syntec for the password
and open Option 2
“Controller upgrades WinCE
system”.
3. Super controller doesn’t
have this error.
Summary of Contents for SmartShop Maker
Page 1: ...SmartShop Maker Owner s Manual Laguna Tools 744 Refuge Way Grand Prairie TX lagunatools com...
Page 6: ...SmartShop Maker Owner s Manual 6 NOTES...
Page 12: ...SmartShop Maker Owner s Manual 12 NOTES...
Page 38: ...SmartShop Maker Owner s Manual 38 NOTES...
Page 66: ...SmartShop Maker Owner s Manual 66 NOTES...
Page 69: ...SmartShop Maker Owner s Manual 69 Laguna Tools Warranty...