1.5HP Mobile Dust Cyclone Manual
40
TROUBLESHOOTING
Symptom
Possible Cause
Possible Solution
Machine
does not
start or a
breaker
trips.
Power supply switched
OFF or is faulty.
Wall fuse/circuit breaker
is blown/tripped.
Faulty remote control.
Remote receiver is faulty.
Incorrectly wired motor
connection.
On-board circuit breaker
is tripped.
Wiring is open/has high
resistance.
Faulty power switch.
Motor is at fault.
Ensure power supply is
ON
and
has the correct voltage.
Ensure adequate circuit size;
install inlet restrictor, replace
weak breaker.
Replace batteries; ensure un-
obstructed line-of-sight and
signal range.
Inspect receiver circuit board;
replace if faulty.
Rewire or call certified service
technician or electrician.
Allow motor to cool, improve
ventilation, press reset button.
Check for broken wires or poor
connections, repair as
necessary.
Replace switch.
Test/repair/replace.
Excessive
vibration or
noise during
operation.
Loose component.
Loose or broken motor
mount.
Motor fan hitting fan
cover.
Bad motor bearings.
Inspect and tighten all
bolts/nuts.
Tighten or replace as needed.
Check fan and cover; replace as
needed.
Rotate shaft manually, check for
grinding (noise) or loose shaft,
replace bearings if needed.
Summary of Contents for PFLUX1
Page 12: ...1 5HP Mobile Dust Cyclone Manual 11 Figure 2 110 Volt Internal Wiring ...
Page 35: ...1 5HP Mobile Dust Cyclone Manual 34 220 Volt Wiring Diagrams Figures 21 22 OPERATION ...
Page 44: ...1 5HP Mobile Dust Cyclone Manual 43 Figure 48 Fan Motor Switch SECTION A Close up view ...
Page 45: ...1 5HP Mobile Dust Cyclone Manual 44 Figure 49 Cyclone Canister Barrel SECTION B Close up view ...
Page 46: ...1 5HP Mobile Dust Cyclone Manual 45 Figure 50 Panels Lock SECTION C Close up view ...
Page 47: ...1 5HP Mobile Dust Cyclone Manual 46 Figure 51 Barrel insert SECTION D Close up view ...