ELECTRICAL
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Before connection, check
:
Main voltage is compatible with the appliance’s rated voltage and thermal output.
Connection:
-
Use a 4-wire cord rated for 30 A 125 / 250 VAC, type SRD, SRDT, S, SO or ST.
-
Cord must be agency approved for use with household ranges.
-
Remove access door
O
(Fig. 31) with 7mm nutdriver
M
(Fig. 32).
-
Remove cable clamp and loosen supply cord mounting screws on the terminal block.
-
Connect to terminal block in accordance with figure 34.
-
Secure the cable by means of cable clamp
(not provided), item
Q
(Figure 33).
-
Refit access door
Page 15 of 38 – US – Date: 26/02/10
Ø
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES
OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition
.
IMPORTANT
Fig. 33
Q
Fig. 32
M
Fig. 34
Ø
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.
O
Fig 31