SERVICE INSTRUCTIONS:
-Lubricating gas valves.
If the gas taps tends to stick slightly, you may follow this procedure:
•
1 - Shut off the valve and / or the main electrical supply of the unit.
•
2 - Take out the knob corresponding to the gas valve to be greased.
•
3 - Unscrew the head from the body of the burner valve.
•
4 - Grease the tap shaft (High temperature lubricant, for example : SILICAL GEL ™ BARBAHL).
Caution! Any excess grease should be removed.
Reverse operation 3 to 1 (in that order) to put valve and knob back on.
-OVERLIMIT THERMOSTAT:
To access internal components and reset the overlimit, lift and secure rangetop.
Press pushbutton item
U
(Figure 38) in order to reset the limiting thermostat.
Note:
ALWAYS IDENTIFY
the reason why the thermostat tripped.
Page 17 of 38 – US – Date: 26/02/10
Fig. 38
U