25
TERMINAL BOARD M3
Terminals 8-11
EXTERNAL RADAR input, N.O. contact.
It controls the door opening.
It is not active when the program selector is set to “Exit Only” and “Night Lock”.
Terminals 9-11
INTERNAL RADAR input, N.O. contact.
It controls the door opening.
It is not active when the program selector is set to “Entry Only” and “Night Lock”.
Terminals 10-11
START input., N.O. contact.
It controls the door opening.
TERMINAL BOARD M4
Connection of the ET-DSEL digital selector
Te
= (power supply positive);
Terminal A
= signal line A;
Terminal B
= signal line B;
Terminal -
= (Power supply negative).
TERMINAL BOARD M5 - OUT2
Terminals 22-23-24
Relay potential free contact RL1 (22 = COMMON 23 = N.C., 24 = N.O.)
The output operation depends on the setting of function F41m (see FUNCTION TABLE).
TERMINAL BOARD M6
Terminal 25
TEST output for the safety sensors set for monitoring.
•
For details, refer to the "Safety sensors" paragraph.
Terminals 26-27
AUX 3 input., N.O. contact.
It is enabled in the applications with interlock (function F26 = ON and F29 = ON).
It controls the door opening in all operating programs.
•
For details, refer to the "Interlock System" paragraph
Terminals 28-29
Open Collector NPN output.
The operation depends on the setting of function F41m (see FUNCTION TABLE).
Connect a max load of 100mA between terminals 29 (O.C.) and 28 (po 24V).
•
In the Interlock function (F26 = ON), terminal 29 is used for the interlock operation connection; for further information, refer to the
“Interlock system” paragraph.
TERMINAL BOARD M7
Terminals 16 (negative) - 17 (positive)
24Vdc, 1A output supplying power to the control and safety sensors.
When the L1 LED is on, the output is working properly.
TERMINAL BOARD M8
Terminals 18-19-20
Relay potential free contact RL3 for electric lock connection (18 = Common 19 = N.O., 20 = N.C.).
Terminals 16 (negative) - 21 (positive)
24Vdc output supplying power to the electric lock or to the electromagnet.
•
For details, refer to the paragraph "Applications with electric lock".
CONNECTORS
Connector J1
= connector for digital selector T-NFC
Connector J3
= connection of the battery module NB-BAT (see para. “Battery module NB-BAT”)
Connector J4
= wiring of electrical signals to connector J10 of the LCB logic card.
Connector J5
= wiring of motor power supply to connector J11 of the LCB logic card.
When LED 1 is on the output voltage is present.