10. Application Guide
86
PLM+ SERIES Operation Manual rev 3.0.1
10.6. Digital Clock Configuration
10.6.1. Digital Clock Overview
clocking system. The digital clock can generate various independent internal sample rates, or can sync to an
incoming AES3 signal. Figure 10.7 shows the various sample rates and options available.
INPUTS
DANTE
C
AES1
48 kHz
AES2
INTERNAL
PRIMARY
CLOCK
48 kHz
96 kHz
192 kHz
C
AES1
48 kHz
AES2
INTERNAL
48 kHz
96 kHz
192 kHz
44.1 kHz
88.2 kHz
176.4 kHz
44.1 kHz
INTERNAL
Pwr 1
C
Pwr 2
C
Pwr 3
C
Pwr 4
C
Dante
C
Channel 1-8
48 / 96 kHz
OUTPUTS
SAMPLE RATE
CONVERTER
CLOCK
C
AUTO /
MANUAL 48
C
AUTO /
MANUAL 44
Table 10.7: Digital Clocking System
In Figure 10.7, each circled C represents a choice point. A choice point is a user-interface control that can be
information.
NOTE: Figure 10.7 indicates internally generated clocks with base-rate multiples of 44.1 kHz or 48 kHz.
This should not be confused with the internal DSP sample rate of 96 kHz.
The PLM+ digital clocking system can either generate its own internal clock, or synchronize to an incoming
external clock source via the AES3 digital input.
10.6.2. Clock Source Priorities
compatible clock signal is preset.