7. Front Panel Interface
58
PLM+ SERIES Operation Manual rev
3.0.1
7.11.6. Front Panel Display Controls
MENU > FRAME > FRONT
Contrast
To adjust the front panel LCD contrast, select this option then use the rotary encoder to change the value.
Dimming
To adjust the front panel LCD & LED brightness, select this option then use the rotary encoder to change the value.
Channel Order
To adjust the order in which both inputs and outputs are displayed on the front panel in all views, select this option
then use the rotary encoder to change the value between TOP-DOWN (default) and BOTTOM-UP.
7.11.7. Frame Preset Menu
MENU > FRAME PRST
To recall an existing Frame Preset, use the rotary encoder to select the required Preset then press the RECALL
button to overwrite the current configuration.
Note: Frame Presets must initially be created in the Lake Controller, and stored as a Preset using the
Lake Controller or the PLM+ Series Preset Manager.
Up to 100 Frame Presets can be stored in the device. The data within a Frame Preset includes the configuration
of all Modules in the Frame including levels, crossovers, EQ, input mixer, and output routing. (Note that Network
settings and the Dual Redundancy setting are not part of Frame Presets.)
As Frame Presets are stored within the device, complete processor configurations can be recalled without
connecting the device to a PC.
7.11.8. Load Monitor Menu (LoadSmart)
MENU > LOAD MON
Figure 7.22: LoadSmart Verification Results Screen