9. Appendix
PLM+ SERIES Operation Manual rev 3.0.1
75
PLM 20K44
Level
Load
Rated power
per channel
Line Current
Power
Factor
Measured Power (W)
Thermal Dissipation
(A)
(%)
In
Out
Dissipated
BTU/hr
kCal/hr
Mains Voltage 100 VAC, 30 A
Standby
0.3
52
17
0
17
58
15
Power on, Idling
2.4
97
235
0
235
802
202
Pink Pseudo
Noise
16 Ω / Ch.
1150
12.1
99
1192
588
604
2061
520
8 Ω / Ch.
2300
22.3
99
2198
1174
1024
3493
881
4 Ω / Ch.
4400
29.2
99
2853
1478
1375
4691
1183
2.67 Ω / Ch.
5000
29.2
99
2862
1399
1463
4991
1259
2 Ω / Ch.
4400
29.1
99
2826
1355
1472
5022
1266
LoadPilot
Sine 20 kHz
8 Ω / Ch.
2.5
97
236
0
236
807
203
Mains Voltage 120 VAC, 30 A
Standby
0.3
48
17
0
17
58
15
Power on, Idling
2.0
97
227
0
227
775
195
Pink Pseudo
Noise
16 Ω / Ch.
1150
12.0
99
1180
588
593
2023
510
8 Ω / Ch.
2300
18.4
99
2144
1174
970
3310
835
4 Ω / Ch.
4400
30.0
99
3457
1896
1561
5326
1343
2.67 Ω / Ch.
5000
29.5
99
3439
1752
1687
5756
1451
2 Ω / Ch.
4400
29.9
99
3495
1665
1830
6245
1575
LoadPilot
Sine 20 kHz
8 Ω / Ch.
2.0
97
232
0
232
790
199
Mains Voltage 208 VAC, 17.3 A
Standby
0.3
27
18
0
18
60
15
Power on, Idling
1.2
92
222
0
222
757
191
Pink Pseudo
Noise
16 Ω / Ch.
1150
5.7
99
1151
588
564
1923
485
8 Ω / Ch.
2300
10.2
99
2055
1174
881
3005
758
4 Ω / Ch.
4400
16.2
99
3286
1948
1338
4565
1151
2.67 Ω / Ch.
5000
15.6
99
3171
1752
1419
4843
1221
2 Ω / Ch.
4400
16.0
99
3253
1665
1589
5420
1367
LoadPilot
Sine 20 kHz
8 Ω / Ch.
1.2
92
229
0
229
780
197
Mains Voltage 230 VAC, 16 A
Standby
0.3
23
18
0
18
61
15
Power on, Idling
1.2
92
222
0
222
757
191
Pink Pseudo
Noise
16 Ω / Ch.
1150
5.1
98
1134
588
546
1863
470
8 Ω / Ch.
2300
9.2
99
2053
1174
879
2999
756
4 Ω / Ch.
4400
15.9
99
3529
2109
1420
4845
1222
2.67 Ω / Ch.
5000
16.0
99
3564
1935
1630
5561
1402
2 Ω / Ch.
4400
16.0
99
3577
1856
1722
5875
1481
LoadPilot
Sine 20 kHz
8 Ω / Ch.
1.1
90
228
0
228
777
196
Table 9.4: PLM20K44 Current Draw and Dissipation Specifications