background image

Page 81

N

EO

T

HERM

 Boilers and Water Heaters

 

 

SIZE 

 SIZE SIZE SIZE SIZE SIZE SIZE SIZE

ITEM  DESCRIPTION 

NTH 150 

NTH 210 

NTH 285 

NTH 399 

NTH 500 

NTH 600 

NTH 750 

NTH 850

 

 

NTV 150  

NTV 199 

NTV 285 

NTV 399 

NTV 500 

NTV 600 

NTV 750 

NTV 850

64  Duplex Outlet Water   RE2319900   RE2319900  RE2319900  RE2319900  RE2319900  RE2319900  RE2319900  RE2319900
 

Temperature Sensor

65  Duplex Stack  

RE2319700   RE2319700  RE2319800  RE2319800  RE2319800  RE2319800  RE2319800  RE2319800

 

Temperature Sensor

66  Pressure Relief Valve,  R51-182  

R51-182 

RA2113602  RA2113602  RA2113602  RA2113602  RA2113602  RA2113602

 

NTH

 

(30 PSI)  

(30 PSI) 

(75 PSI) 

(75 PSI) 

(75 PSI) 

(75 PSI) 

(75 PSI) 

(75 PSI)

 

Pressure Relief Valve,  A2114802  

A2114802 

A2114802 

A2114802 

A2114802 

A2114802 

A2114802 

A2114802

 

NTV

 

(125 PSI)  

(125 PSI) 

(125 PSI) 

(125 PSI) 

(125 PSI) 

(125 PSI) 

(125 PSI) 

(125 PSI)

67 

Air 

Vent 

R1-592 

 R1-592 R1-592 R1-592 R1-592  R1-592 R1-592 R1-592

68  Burner Door w/gasket  RS2112801   RS2112801  RS2112801  RS2112801  RS2112801  RS2112801  RS2115301  RS2115301
68A Gasket-only

  (rubber only)

 

R2069400 

 R2069400 R2069400 R2069400 R2069400  R2069400 R2077400 R2077400

69  Burner Gasket 

RS2108500   RS2108500  RS2108500  RS2108500  RS2108500  RS2108500  S2113000 

S2113000

69A  Gasket Set  

RS2109100   RS2109100  RS2109100  RS2109100  RS2109100  RS2109100  R2077600 

R2077600

 

(burner gasket, ignitor gasket, sensor gasket & rubber door gasket)

70  Front Refractory Tile 

RT2109001   RT2109001  RT2109001  RT2109001  RT2109001  RT2109001  T2110300 

T2110300

71 Rear 

Refractory 

Tile  R50D2021 

 R50D2021 R50D2021 R50D2021 R50D2021  R50D2021 R50D2021 R50D2021

72  Main Burner w/gasket  R2069103   R2069104 

R2069105 

R2069106  R2069106 

R2069107 

R2069108 

R2069109

73  Flame Sensor w/gasket  R2069200   R2069200 

R2069200 

R2069200  R2069200 

R2069200 

R2071400 

R2071400

74 

Ignitor 

w/gasket 

R2069300 

 R2069300 R2069300 R2069300 R2069300  R2069300 R2071500 R2071500

74A Ignitor 

Gasket 

RW2013300 

 RW2013300 RW2013300 RW2013300 RW2013300  RW2013300 RW2013300 RW2013300

74B Screw, 

Ignitor/ 

m4-.7X8mm 

 m4-.7X8mm m4-.7X8mm m4-.7X8mm m4-.7X8mm  m4-.7X8mm m4-.7X8mm m4-.7X8mm

 

Flame 

Sensor 

S2112700 

 S2112700 S2112700 S2112700 S2112700  S2112700 S2112700 S2112700

74C Flame/Sensor 

Gasket RW2013400 

 RW2013400 RW2013400 RW2013400 RW2013400  RW2013400 RW2013400 RW2013400

75  Air/Gas Channel

 (80-600)

 RS2108600 RS2108700 RS2108700 RS2108700 RS2108801  RS2108801 RS2115400 RS2115400

 

Air Adapter

 (750-850)

75A 

Screw, 

Air/Gas 

RS2109400 

 RS2109400 RS2109400 RS2109400 RS2109400  RS2109400 RF2029200 RF2029200

 

Channel 

(5) 

 (5) (5) (5) (5)  (5) (5) (5)

76 

Drain 

R10-143 

 R10-143 R10-143 R10-143 R10-143  R10-143 R10-143 R10-143

77 Sight 

Glass 

R50D2020 

 R50D2020 R50D2020 R50D2020 R50D2020  R50D2020 R50D2020 R50D2020

Electrical Components – 

See Parts Illustration 8

 

 

  

  

  

 

80 

Control  Panel 

Enclosure 

R50D7001 R50D7001 R50D7001 R50D7001 

 R50D7001  R50D7001 R50D7001 R50D7001

81 Transformer 

RE2108700 

 RE2108700 RE2108700 RE2108700 RE2108700  RE2108700 RE2108700 RE2108700

82  High Voltage Shield 

R50D7002   R50D7002 

R50D7002 

R50D7002  R50D7002 

R50D7002  R50D7002 

R50D7002

83  Top Panel Bracket 

R50D7003   R50D7003 

R50D7003 

R50D7003  R50D7003 

R50D7003  R50D7003 

R50D7003

84  Electronic Control  

   

 Contact Customer Service at 800 900-9276 x11

 

Module, Standard

84  Electronic Control 

 

    

Contact Customer Service at 800 900-9276 x11

 

Module, CSD-1

85 Rocker 

Switch 

RE2322700 

 RE2322700 RE2322700 RE2322700 RE2322700  RE2322700 RE2322700 RE2322700

87 Wire 

Harness 

R50D7412 

 R50D7414 R50D7408 R50D7406 R50D7402  R50D7410 R50D7409 R50D7409

89  Air Pressure Switch 

RE2334700   RE2334701  RE2334700 

— 

RE2334700  RE2334700  RE2334701  RE2334700

90  Water Flow Switch 

— 

— 

— 

R2008400  R2008400 

R2008400 

R2008400 

R2008400

Summary of Contents for NTH

Page 1: ...in flue gases which could cause serious injury property damage or death Improper installation and or operation will void the warranty Indoor Outdoor AVERTISSEMENT Assurez vous de bien suivres les inst...

Page 2: ...ments 23 5 2 NeoTherm Water Heater Flow and Head Requirements 23 Section 6A Water Connections NTH Boiler 6A 1 NTH System Piping Hot Supply Connections 24 6A 2 NTH Cold Water Make Up 24 6A 3 Condensate...

Page 3: ...h Screen 8 1 The Touch Screen 41 8 2 Using the Touch Screen 41 8 3 Verification Process for Safety Related Parameters 43 8 4 While Operating Checking Individual Parameters 44 8 5 Configuring Parameter...

Page 4: ...LAARS Heating Systems...

Page 5: ...ceed 13 W C 3 2kPa All installations must be made in accordance with 1 American National Standard Z223 1 NFPA54 Latest Edition National Fuel Gas Code or 2 CSA B149 1 Natural Gas and Propane Installati...

Page 6: ...th variations of the NeoTherm have the On Off switch on the outside of the unit DOOR HANDLE PULL TO OPEN RELEASE BOTH LATCHES TO OPEN DOOR LATCHES ON OFF SWITCH THE TOUCH SCREEN ON OUTDOOR UNIT IS LOC...

Page 7: ...ure 3 Connection piping is on the BACK for ALL Outdoor Sizes WATER INLET WATER OUTLET AIR INLET FILTER BOX CONDENSATE TRAP GAS VALVE PRV must be added to this pipe during installation GAS CONNECTION E...

Page 8: ...WATER OUTLET PRESSURE RELIEF VALVE AIR PRESSURE SWITCH DRAIN VALVE CONDENSATE TRAP AIR TRANSITION ON OFF SWITCH Figure 4 Location of Components Sizes 150 210 EXHAUST VENT CONNECTION GAS CONNECTION AIR...

Page 9: ...DRAIN VALVE CONDENSATE TRAP GAS VALVE ON OFF SWITCH Figure 6 Location of Components Indoor Size 399 Figure 7 Location of Components Indoor Size 500 EXHAUST VENT CONNECTION PRESSURE RELIEF VALVE TOUCH...

Page 10: ...RESSURE SWITCH WATER INLET WATER OUTLET AIR INLET CONNECTION DRAIN VALVE CONDENSATE TRAP GAS VALVE MANUAL SHUTOFF GAS VALVE ON OFF SWITCH Figure 9 Location of Components Sizes 750 and 850 WATER INLET...

Page 11: ...ET WATER INLET WATER OUTLET WATER OUTLET AIR INLET FILTER BOX AIR INLET CONDENSATE DRAIN CONDENSATE DRAIN Outdoor 850 MBH Indoor 850 MBH Figure 10 Connection piping is on TOP for ALL Indoor Sizes Figu...

Page 12: ...0 4 11 14 37 18 47 19 49 16 42 21 55 18 48 13 33 500 NTH 30 77 5 13 19 50 4 11 15 38 20 51 20 52 19 48 26 66 18 48 13 33 500 NTV 30 77 5 13 19 50 4 11 15 38 20 51 20 52 19 48 26 66 18 48 13 33 600 bot...

Page 13: ...Page 9 NEOTHERM Boilers and Water Heaters 38 1 2 98 8 3 4 22 7 1 2 19 64...

Page 14: ...0 18 45 7 27 69 24 1 2 60 285 6 15 5 11 28 5 13 17 1 4 43 8 24 61 19 48 28 1 4 72 12 30 5 399 8 15 5 19 1 2 50 7 3 4 20 17 1 4 43 8 24 61 19 48 28 1 4 72 12 30 5 500 5 13 17 3 4 45 5 13 8 1 4 21 24 61...

Page 15: ...2 3 4 83 2 3 0 8 5 1 4 13 4 17 1 4 43 8 24 61 19 48 29 1 4 74 12 E F A B C D G in cm in cm in cm in cm in cm in cm 8 45 7 27 69 23 1 2 60 5 1 4 13 20 60 3 7 6 8 45 7 27 69 24 1 2 60 5 1 4 13 27 68 6 3...

Page 16: ...r damage Any such claims should be filed with the carrier The carrier not the shipper is responsible for shortages and damage to the shipment whether visible or concealed 1 7 Unpacking The NeoTherm un...

Page 17: ...uld be met when choosing the locations for the appliance 2 2 Locating Appliance for Correct Vent Distance from Outside Wall or Roof Termination The forced draft combustion air blower in the appliance...

Page 18: ...TAxx ID Horizontal Termination bird screen 9x92 FSBSx 2SVSTPXxx Vertical Termination rain cap 5X00CI FSRCx 2SVSRCxx Inlet Air Termination 9xTERM FSAIHXX 2SVSTEXxx90 Adapter SS to CPVC FSA xxFNSM xPVCF...

Page 19: ...ES CANADA ABS ANSI ASTM D1527 PVC sch 40 ANSI ASTM D1785 or D2665 Air pipe material must be chosen CPVC sch 40 ANSI ASTM F441 based upon the intended application of the boiler Single wall galv steel 2...

Page 20: ...nal not less than 1 4 per foot so that condensate will run back to the NeoTherm and drain out thru the condensate trap Horizontal portions of the venting system must be supported to prevent sagging an...

Page 21: ...rature of more than 135 C but not more than 245 C Class II venting systems are suitable for gas fired appliances producing flue gas temperatures of 135 C or less Class II venting systems are further c...

Page 22: ...operating issues Side Wall Combustion Air Terminal The LAARS side wall combustion air terminal or concentric terminal must be used when the heater takes air from a side wall See page 15 Contact Laars...

Page 23: ...r vent outlet See note 4 3 feet 91 cm J Clearance to nonmechanical air supply Direct vent only 12 30cm 80 285 36 91cm inlet to building or the combustion air inlet 399 850 Other than Direct vent 4 ft...

Page 24: ...ructure served by the side wall horizontally vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for installatio...

Page 25: ...nimale d termin e en utilisant les tableaux appropri s et des lignes directrices dans le National Code de gaz combustible ANSI Z223 1 NFPA 54 et ou CSA B149 1 Codes d installation 3 5 Common Vent Test...

Page 26: ...y lines and or an obstructed gas supply line Some NeoTherm units are equipped with low and high gas pressure switches that are integrally vent limited These types of devices do not require venting to...

Page 27: ...LOW H L SIZE GPM FT GPM FT GPM FT GPM FT GPM FT 150 14 3 28 5 11 4 19 9 5 13 6 8 1 11 2 7 1 8 8 199 210 20 24 1 16 16 7 13 4 11 6 11 3 9 9 9 6 9 285 27 25 5 22 17 5 18 14 15 10 5 13 8 399 39 28 31 20...

Page 28: ...ed above radiation level or as required by the authority having jurisdiction must be provided with a low water cutoff device either as a part of the boiler or at the time of boiler installation NTH PI...

Page 29: ...boiler is subjected to freezing conditions and the boiler is not able to fire and or the water is not able to circulate there is a risk of freezing in the boiler or in the pipes in the system When wat...

Page 30: ...Page 26 LAARS Heating Systems Figure 21 Hydronic Piping Single Boiler Zoning with Circulators...

Page 31: ...Page 27 NEOTHERM Boilers and Water Heaters Figure 22 Hydronic Piping Single Boiler Low Temp Radiant Space Heating Using Low Loss Header and Zone Valves...

Page 32: ...Page 28 LAARS Heating Systems Figure 23 Hydronic Piping Multiple Boilers Zoning with Circulators...

Page 33: ...Page 29 NEOTHERM Boilers and Water Heaters Figure 24 Hydronic Piping Multiple Boilers with Indirect DHW Tank Piped from System Loop...

Page 34: ...Page 30 LAARS Heating Systems Figure 25 Hydronic Piping Multiple Boilers Reverse Return Multi Temp Zones Zoning with Circulators...

Page 35: ...ilers and Water Heaters Figure 26 Hydronic Piping Heating Zones with Indirect DHW Tank Piped with Zone Pumps The indirect DHW tank is piped directly off of the boiler The boiler pump must shut down du...

Page 36: ...Page 32 LAARS Heating Systems Figure 27 Hydronic Piping Multiple Boilers with Indirect DHW Off of One Boiler The boiler pump must shut down during DHW operation...

Page 37: ...n 6A covers NTH units designed for hydronic heating Section 6B covers NTV models which are designed exclusively for volume water domestic hot water applications Refer to the proper section for instruc...

Page 38: ...H 5 and may harm some floor drains and or pipes particularly those that are metal Ensure that the drain drainpipe and anything that will come in contact with the condensate can withstand the acidity o...

Page 39: ...ack flow preventer may be required check local codes 4 Thermal expansion tank may be required check local codes 5 Factory mounted pumps are sized for a max pipe length of 30 total 6 90 elbows full pip...

Page 40: ...on water hardness at job site WARNING This drawing shows suggested piping configuration and valving Check with local codes and ordinances for additional requirements NOTES 1 Optional CWMU Recirc line...

Page 41: ...d be electrocuted by an ungrounded boiler Electrocution can result in severe injury or death Single pole switches including those of safety controls and protective devices must not be wired in a groun...

Page 42: ...aximum 1HP No Pump or 7 4A max 199 500 Less With Pump 120 Single than 115V Maximum 1HP 6 or 7 4A max Minimum 15A circuit required Table 15 NTH Electrical Data Figure 32 Control Panel Layout Figure 34...

Page 43: ...by removing the supplied jumpers 7 6 Connections to a Building Automation System NeoTherm boilers can be controlled and monitored through the included Modbus ports The Modbus wiring should be complete...

Page 44: ...R Y BRN BRN WH WH R TO TB2 PIN2 TO XFORMER WH TO TB1 PIN2 TO XFORMER BLK FLOW SWITCH R ADD L HIGH LIMIT BL Y GR BL GR VT WH GY FIELD INSTALLED OPTIONS LOW WATER CUTOFF GY R BLK BLK Y WH WH VT GY BL Y...

Page 45: ...h the screen to wake it up While under normal operation the Touch Screen will automatically present this Home screen See Menu 1 Menu 1 Home Screen Menu 2 Status Summary The home screen shows a picture...

Page 46: ...LNT User Level no password required Non critical adjustments and functions including adjusting the Central Heat and Domestic Hot Water setpoints monitoring the input and output variables reading param...

Page 47: ...ormation on logging in see Section 8 2 2 If you make a change in any group that could affect the safe operation of the unit the control system will ask you to verify the change before it is accepted 3...

Page 48: ...ill be cancelled A count down timer is shown at the bottom of the screen 8 4 Checking Individual Parameters 1 From the Home screen Menu 9 press the icon for the controller Menu 9 Home screen 2 The Sta...

Page 49: ...Home Page screen Menu 11 press the icon for the controller Menu 11 Home Page Screen 2 The Status Summary page for that controller will appear See Menu 12 Menu 12 Status Summary Screen 3 Press the Con...

Page 50: ...n Menu 14 Home screen 2 Press the Setup button on the lower right corner of the screen The system will present the Setup screen Menu 15 Setup Screen 3 Press the Display Setup button at the bottom of t...

Page 51: ...ion regarding software date codes model numbers and program name as well as giving the installer access to re name the boiler and to change the modbus addresses for lead lag operation 8 7 2 CH Central...

Page 52: ...ulation Configuration From this sub menu the installer has the ability to adjust the range of modulation for the CH and DHW demands NeoTherm is designed with a 5 1 turn down ratio Any change to the mi...

Page 53: ...rminal wired to the pump or a relay controlling the pump Additional 120VAC circuits may be required for the pumps 8 7 9 Statistics Configuration The statistics configuration sub menu allows the instal...

Page 54: ...the time allowed for an alarm to sound before being silenced 8 7 15 Fan Configuration To increase decrease the speed at which the fan control loop reacts to a decrease in fan speed adjust the Fan gai...

Page 55: ...Lead Lag Leader A Run sequence is initiated when the system temperature falls to the Lead Lag Central Heat setpoint Actually this is the LL CH setpoint less the On Hysteresis value The default settin...

Page 56: ...the heating demand increases so that the firing rate of that first boiler rises to your boiler configurations Base Load Value see Figure 42 the next boiler in the sequence will start up and begin fir...

Page 57: ...Configuration In the Lead Lage Follower Sub Menu Identify each unit including the Lead Lag Leader as a Follower by turning on Follower Enable 8 7 17 Lead Lag Follower Configuration Menu 21 Home Screen...

Page 58: ...oor lock and then opening the doors The wiring from the controller on the first boiler runs to the controller on the next boiler Use 22 AWG or thicker shielded twisted pair wire with drain Two twisted...

Page 59: ...485 Figure 45 BAS connnections to a Lead Lag System Lead or master boiler Controller Controller Master System display TB3 24VAC TB4 NEU Operator interface HMI Customer communication RS 485 MB1 MB1 MB...

Page 60: ...em will present the Status Summary screen Menu 26 Status Summary Screen 4 Press the Configure button in the lower left corner Menu 27 Configuration Menu 5 NeoTherm is equipped with a zero governing ne...

Page 61: ...turn the High Fire adjustment screw counter clockwise To lower the high fire CO2 level turn the screw clockwise 9 Repeat step 8 except this time set the fan speed RPM to 1200rpm Again the actual RPM w...

Page 62: ...esidential sizes 150 285 Mbtu CO2 Range and Differential Pressure GAS TYPE HIGH FIRE CO2 LOW FIRE CO2 MANIFOLD PRESSURE Natural 8 8 to 9 0 0 5 lower than 005 to Propane 9 8 to 10 0 high fire setting 0...

Page 63: ...ire CO2 adjustment under cap Gas pressure tap Low fire CO2 adjustment Outlet gas pressure Inlet gas pressure Low fire CO2 adjustment High fire CO2 adjustment under cap Outlet gas pressure Gas pressure...

Page 64: ...has been bled from both Open all valves 3 Observe all warnings on the Operating Instructions Section 9 First Start Up and Adjustment 9 1 Filling the Boiler System 1 Ensure the system is fully connecte...

Page 65: ...ain and the burner will start The appliance will return to its previous mode of operation DANGER If you detect any odor of gas or if the gas burner does not appear to be functioning in a normal manner...

Page 66: ...ong life and dependable operation but the safety of equipment depends on their proper functioning Only a qualified service technician should inspect the basic items listed below every year Burner Chec...

Page 67: ...l board The control board connections are keyed to only allow connection in the proper location but proper handling techniques should be used to avoid damage to the wiring or connectors To remove the...

Page 68: ...door blower arm If the fan is determined to be defective replace the existing fan with a new one reversing the steps listed above Be sure to install all of the required O rings and gaskets between the...

Page 69: ...w c For propane set the low gas pressure switch to 5 w c For natural and propane set the high gas pressure switch to 14 10 3 Battery Backup for Date Time The touchscreen does have an internal battery...

Page 70: ...artup This indicates that the control system is waiting for a condition to be satis ed No Reset is required to recover from an alert The system maintains a history of the 15 most recent alerts Sometim...

Page 71: ...of the last 15 Lockout occurances Press Alerts to bring up a list of the last 15 Alerts and Silence Alarm in the event of a lockout condition By silencing the alarm the audible alert has been disable...

Page 72: ...module 2 Waiting for safety data veri cation L 1 Device in Con guration mode and safety parameters need veri cation and a device needs reset to complete veri cation 2 Con guration ended without veri...

Page 73: ...e starts H 24 Internal fault Spark voltage stuck low or high H 25 Internal fault Spark voltage changed too much during ame sensing time H 26 Internal fault Static ame ripple H 27 Internal fault Flame...

Page 74: ...imit Control Input OFF H 1 Check wiring and correct any faults 2 Check Interlocks connected to the LCI to assure proper function 3 Reset and sequence the module monitor the LCI status 4 If code persis...

Page 75: ...t persists replace the module 92 Outlet sensor fault H 1 Check wiring and correct any possible errors 2 Replace the Outlet sensor 3 If previous steps are correct and fault persists replace the module...

Page 76: ...ption Will not be a lockout fault Hold Only Internal hardware test Not a lockout 111 Flame current lower than weak threshold H Hold time of recycle and hold option Will not be a lockout fault Hold Onl...

Page 77: ...to the correct terminal 3 Make sure the F G wires are protected from stray noise pickup 4 Reset and sequence the module if code reappears replace the ame detector 5 Reset and sequence the module if c...

Page 78: ...nvalid interlock start check setting L 199 Invalid LCI Limit Control Input enable setting L 200 Invalid lightoff rate setting L 201 Invalid lightoff rate proving setting L 202 Invalid MFEP Main Flame...

Page 79: ...Outlet high limit setpoint setting L 227 Invalid DHW Domestic Hot Water high limit setpoint setting L 228 Invalid Stack limit setpoint setting L 229 Invalid Modulation output setting L 230 Invalid CH...

Page 80: ...displayed The Burner Control I O button leads to Menu 8 Menu 8 Burner Control I O Screen A green dot indicates a function that is on 2 Press the Digital I O button to see parameters with the functions...

Page 81: ...ehavior over a period of time for several different parameters fan speed outlet temperature inlet temperature etc Menu 15 Analysis Setup Screen To use this function select the parameter you want to tr...

Page 82: ...equipped with a low and high re air pressure switch The unit will pre purge at 65 fan for 30 seconds and prove fan through the blocked intake switch Once fan is proven the blower will proceed to 24 an...

Page 83: ...upport R50D3004 R50D3004 R50D3004 R50D3004 R50D3004 R50D3004 R50D3004 R50D3004 Right Stanchion 12 Front Bezel R50D7121 R50D7121 R50D7121 R50D7121 R50D7121 R50D7121 R50D7121 R50D7121 13 Touchscreen Dis...

Page 84: ...0100 RP2050100 46 Gas Valve Venturi RS2104900 RS2104900 RS2104900 RS2104900 Cork Gasket 47 Gas Valve O Ring R30 227 R30 227 R30 227 48 Venturi O Ring RS2105200 RS2105200 RS2105200 RS2105200 RS2105200...

Page 85: ...2069200 R2069200 R2069200 R2071400 R2071400 74 Ignitor w gasket R2069300 R2069300 R2069300 R2069300 R2069300 R2069300 R2071500 R2071500 74A Ignitor Gasket RW2013300 RW2013300 RW2013300 RW2013300 RW201...

Page 86: ...Page 82 LAARS Heating Systems Parts Illustration 1 Jacket Components...

Page 87: ...Page 83 NEOTHERM Boilers and Water Heaters Parts Illustration 2 Internal Components Sizes 150 210 Parts Illustration 3 Internal Components Sizes 285 600...

Page 88: ...Page 84 LAARS Heating Systems Parts Illustration 4 Internal Components Sizes 750 850...

Page 89: ...Page 85 NEOTHERM Boilers and Water Heaters Parts Illustration 5 Gas Train Components Sizes 150 500 Sizes 150 285...

Page 90: ...Page 86 LAARS Heating Systems Parts Illustration 6 Gas Train Components Sizes 600 850...

Page 91: ...Page 87 NEOTHERM Boilers and Water Heaters Parts Illustration 7 Heat Exchanger Components 68A Sizes 285...

Page 92: ...Page 88 LAARS Heating Systems Parts Illustration 8 Electrical Components Front Battery CR2032 Touchscreen Back...

Page 93: ...Page 89 NEOTHERM Boilers and Water Heaters Notes...

Page 94: ...Page 90 LAARS Heating Systems Notes...

Page 95: ...Page 91 NEOTHERM Boilers and Water Heaters Notes...

Page 96: ...Fax 603 335 3355 1869 Sismet Road Mississauga Ontario Canada L4W 1W8 905 238 0100 Fax 905 366 0130 www Laars com Printed in U S A Laars Heating Systems 1604 Document 1330B Dimensions and specification...