32
Vertical Installation (recommended)
Table 4
– Approved IPEX Concentric Terminals
Bradford White Appliance
Numbers Approved for
Concentric Termination Kits
Description
Bradford
White Part
Number
IPEX System
(1738 or 636)
IPEX Part
Number
120T(400,500)
3" Concentric
Termination
239-44069-01
636
196006 (PVC),
197009 (CPVC)
120T(400,500)
3" Concentric
Termination
---
1738
397006
120T(400,500)
4" Concentric
Termination
---
636
196021 (PVC),
197021 (CPVC)
120T(400,500)
4" Concentric
Termination
---
1738
397021
Deduct 30 ft (9.2 m)
for 3” concentric terminal ONLY for the 120T(400,500).
Note:
The vent length
must
be reduced by 30 ft
(9.2 m)
when using 3 in
(7.6 cm)
concentric terminals, for a
maximum 3 in
(7.6 cm)
combined vent length of 100 ft
(30.5 m)
. There is
NO
reduction in vent length when
using 4 in
(10.2 cm)
concentric terminals, for a maximum 4 in
(10.2 cm)
combined vent length of 200 ft
(61 m)
plus the 4 in
(10.2 cm)
concentric terminal.
1.
Become familiar with the approved concentric terminals listed in Table 4. Refer to instructions inside
concentric vent kit. Refer to the previous section on determining the maximum venting distance and pipe
diameter required for the installation
.
Figure 20 - Dimensional Layout of
3” & 4” Concentric Vent Kits
Concentric Vent Size
(A) Nominal Pipe Size
(B) in inches
4 in
4 in
6 5/8 in
3 in
3 in
4 ½ in
Figure 21
– 3” & 4” Concentric Vent Kits Part Identification
Concentric Vent Size
(A) in inches
(B) in inches
4 in
4 ½ in
6 5/8 in
3 in
3 in
4 ½ in
Summary of Contents for LUHE120T
Page 42: ...42 BMS Wiring Diagram...
Page 44: ...44 Lighting and Shutdown Instructions Figure 31 Lighting Instruction Label...
Page 62: ......
Page 63: ......