Installation 

17 

 

 

 

Basic Troubleshooting

 

 

 

Problem

 

Solution

 

 

 

The heater does not work or works intermittently. 

 

 
 

 

 
 

1.

 

Flow switch works properly.

2.

 

At the wires from the flow switch, ohm meter should

read Open without flow and Closed with flow.

3.

 

Water flow through the heater is adequate to activate

the flow switch at 0.5 gpm (1.9 lpm) or at the low flow

 

options of 0.15 (0.6 lpm) or 0.25 (0.9 lpm) gpm.

4.

 

Heater is wired with the proper breaker and wire size.

 

5.

 

Refer to Electrical Specificaitons for Heater table in

section 3 for proper requirements.

Unit is receiving voltage from all three phases of the 

power

 

 source. A load voltage reading is also helpful.

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn power OFF before recording any Ohm readings.

 

 

If the above steps do not solve the problem, some additional checks may be performed. Follow the schematic 

to perform the following continuity checks:

 

 

High temperature bimetals (Manual Reset Safeties) .

 

 

Optional ground fault breaker must be in the closed position for the unit to work.

 

 

All internal breakers must be in the ON position for the unit to work.

 

For additional information on Troubleshooting or other information, contact Laars Technical Support. 

Please have Model No. and Serial No. available when seeking technical assistance. Serial No. tag is located 
in the enclosure on the upper left hand corner of the back plate

.

 

Please record and maintain this information at all times:

 

H Series Model No.  

  

Serial No.   

 

 

Summary of Contents for H Series

Page 1: ...TEH006 LCTEH010 LCTEHV010 LCTEH015 LCTEHV015 LCTEH018 LCTEHV018 LCTEH025 Voltage options 208V Single Three Phase 240V Single Three Phase 277V Single Phase 380V Three Phase 400V Three Phase 415V Three...

Page 2: ...allation 6 7 Electric Installation 8 Start Up Check List 9 Start Up 10 Digital Controller Operation 11 NEMA 4 4X Digital Controller Operation 12 Perform Operational Test No 1 13 Perform Operational Te...

Page 3: ...nnect power supply before performing any work in the enclosure Failure to ground this system may result in death or serious injury Make sure that all water supply lines have been flushed and then comp...

Page 4: ...0 F 60 C For applications utilizing quick close valves or solenoid valves it is important to install a hammer arrestor or surge tank close to the point of use to absorb pressure spikes Installation Co...

Page 5: ...and other plumbing for service maintenance Set heater in a vertical upright position with the water outlet located at top Depending on the application the unit may also be installed rotated clockwise...

Page 6: ...any drop to eliminate trapped air Install one union on the water inlet side of the heater and another union upstream of the 100 Mesh 150 micron y strainer Install one union on the water outlet side of...

Page 7: ...Installation 7 2 Plumbing Installation cont...

Page 8: ...Table 310 15 for 75 C insulated copper wire 30 C Ambient Aluminum wire requires larger gauges Not all available optional voltages are listed in the table For standard enclosures remove the four screws...

Page 9: ...nstalled after pressure and temperature relief valve on outlet if required by local or national plumbing codes If the hot water process is not at the highest point in the plumbing loop then an automat...

Page 10: ...ge elements and cause heater malfunction Turn on the connected process observe output temperature rise to setpoint On standard controller set point and output temperatures are located side by side On...

Page 11: ...the controller Keys and Displays Function Setpoint Up and Down Buttons In the Home Page adjusts the set point in the right display In other pages changes the upper display to a highter or lower value...

Page 12: ...e of the controller Keys and Displays Function Setpoint Up and Down Buttons In the Home Page adjusts the set point in the right display In other pages changes the upper display to a highter or lower v...

Page 13: ...he inlet water temperature is equal to or greater than the temperature set on the digital controller 9 Perform Operational Test No 2 Each model has precise specifications for temperature rise capabili...

Page 14: ...tuation FDS Fused Disconnect Internal fused disconnect interlocks with enclosure door when energized prohibiting access to a live cabinet Select the FDS option for an additional level of safety and co...

Page 15: ...ere hard water sediment is present in the water To clean the Y Strainer 1 Turn the power off at the circuit breaker panel 2 Shut off the installer supplied cold water isolation valve to the heater 3 R...

Page 16: ...mperature or faulty sensor Turn power off Check for loose or disconnected wires Check the incoming service connection Voltage must match name plate rated voltage Labels are located on the upper left o...

Page 17: ...urce A load voltage reading is also helpful Turn power OFF before recording any Ohm readings If the above steps do not solve the problem some additional checks may be performed Follow the schematic to...

Page 18: ...DC Option Pin Out D1 Option Pin Out Pin Name Description Pin Name Description T R 2 RS 485 Transmit Receive Non Inverting Input Output Negative 3 Return Current Path for Current Pin 4 3 Signal Ground...

Page 19: ...UINT RWES Remote Set Point Control Mode Process Value 1999 000 to 9999 000 F 1128 000 to 5537 000 C 402 402 Float R Process Value Control Mode OFF 62 Auto 10 Manual 54 1880 2360 Auto UINT RWES Contro...

Reviews: