S1 Dream-T Espresso Machine
Owner’s Manual
Page 17
Alarms
The Dream machine has built in diagnostics to notify the user of a potential problem with
the machine. The alarms will appear on the display and will also show in the alarms menu.
Sometimes an alarm will appear if there is a change in water pressure or a power surge
and may not be an indication of a problem. Some alarms will still allow the machine to
function and others will block it out until the alarm is cleared and problem is resolved. If an
alarm appears then unplug the machine and plug it back in. Turn it back on and then go
into the alarms menu to clear the alarm. If the alarm re-appears then follow the instructions
below or call an authorized service center for assistance.
Coffee Group Temperature Probe Failure
The coffee boiler temperature probe is damaged.
Check connections at probe and control board and then reset the alarm. If problem persists
then replace coffee boiler temperature probe.
Boiler Temperature Probe Failure
The steam boiler temperature probe is damaged. Check
connections at probe and control board and then reset the alarm. If problem persists then
replace steam boiler temperature probe.
MAT Temperature Probe Failure
MAT feature not available at this time so if this alarm
appears then that means the MAT feature has been activated in the current user profile.
To clear alarm, enter the user profile and turn off the MAT feature. After disabling the MAT
feature go into the alarms menu to reset the MAT alarm.
Boiler Refill System Failure
This alarm appears if the steam boiler refill system has been
active for over a minute. This may appear on the first time set up of the machine in which
case cycling the machine on and off should solve the problem. If not then for plumbed in
models make sure the water is turned on to the machine and the filter or softening system
is not clogged.
For reservoir models make sure the water reservoir is filled and properly inserted into the
machine. If using a softener in the reservoir then make sure it is standing in an upright
position and has not yet expired. Try removing the softener to see if the problem persists.
If problem still persists then contact an authorized repair center.
Failed Boiler Temperature
This alarm will appear if the steam boiler has not reached at
least 60°C/140°F within 12 minutes of turning the steam boiler on. Try turning the machine
on and off to clear the alarm. For 15 amp machines it will only heat 1 boiler at a time and
will always give priority to the coffee boiler so if a lot of water is removed from the coffee
boiler then it will prevent the steam boiler from heating until the coffee boiler reaches
temperature. Refrain from using the coffee boiler until the steam boiler has reached
temperature. If problem persists then check the resettable hi-limit switch on the steam
boiler and check wire terminals going to the steam boiler heater for a good connection.
Check steam heater for resistance and for a short and proper continuity.