B - AUTOMATIC Thermostat
(placed in the upper right-hand part of the back
C
)
The thermostat has the task of automatically increasing or decreasing combustion.
Dependent on the position chosen, the thermostat will act on the valve which regulates the intake of air into the furnace, placed on the
back of the cooker. Turn it in a clockwise direction from 0 to 5 to make up the fire and in an anti-clockwise direction to reduce combustion.
As this is an extremely precise device, it is advisable to turn it carefully and never force the knob.
C - FLUE GAS Register
(
Pos.
D
)
(Conversion from the cooker
HOTPLATE USE
–
OVEN USE
function to the cooker
HEATING
function)
On the right of the front of the stove/cooker, between the protection rail and the oven door, is the smoke-register control lever, recognisable
as a bronze knob. When the lever is pushed towards the back of the stove/cooker, the combustion gases flow above the oven directly
towards the exhaust stub (cooker function – PLATE USE); when the lever is pulled towards you, the combustion gases flow all around
the oven, so the internal temperature increases evenly (cooker – oven cooking and heating – OVEN USE).
To ignite the flame
follow the instructions below (see Cap. IGNITION) :
• Open the ignition register to aid flue gas exhaust. Position the register (any butterfly valve placed on the flue gas exhaust pipe must
also be opened).
• Position the thermostat knob on position 5 (maximum opening).
• Open the primary air register (placed on the ash tray).
• After having started the fire with small pieces of wood and waited until it is well lit, adjust the thermostat to the positions corresponding
to the desired heat (0÷5).
• Bring the flue gas register to the oven position.
• Close the any butterfly valve placed on the flue gas exhaust pipe must also be opened.
The register regulation necessary in order to obtain nominal calorific output is the following
(see Cap. TECHNICAL DATA)
:
Fuel
PRIMARY air
SECONDARY air
TERTIARY air
WOOD
CLOSED
OPEN
Pre-adjusted
5.1. DIGITAL ELECTRONIC CONTROLLER FOR WATER HEATERS
5.1.1. ELECTRIC CONNECTION
The control unit and the plant must be installed and connected by authorized personnel according to the standards in force.
Connect the feeding cable of the switchboard with an electronic bipolar switch respecting at least a 3 mm distance between the contacts
(power supply 230V~ 50 / 60Hz, it is necessary to provide for the correct connection to the grounding plant).
WARNING
: The COMMAND must be connected to the mains with a differential line cut-off switch according to the regulations in force.
Correct operation of the appliance is only guaranteed for pumps and valves approved by La Nordica. La Nordica is not liable for any
improper use of the appliance.
WARNING: In any case, the power cable has to be replaced by authorised personnel ONLY
(entitled by La Nordica):
authorised dealers and/or fitter.
5.1.2. OPERATION
This digital electronic device controls the activation of two circulating pumps and see chapter EXTRA FUNCTIONS.
The digital controller, as well as controlling the water temperature, also manages any blockage of the pumps in the thermocooker.
Correct operation of the appliance is only guaranteed for pumps and valves approved by La Nordica.
La Nordica is not liable for any
improper use of the appliance
.
The internal menu can be used to:
• set the language used to show information on the display (IT-EN-DE-FR);
• set the temperature in °C o °F;
• enable or disable the alarm buzzer (Buzzer);
• change display brightness;
• access the technical menu.
WARNING:
the parameters in the technical menu should never be modified. Such operation must only be performed by an authorised La
NORDICA S.p.A.
Service Centre.
La NORDICA S.p.A. is not liable for product malfunctions due to the parameters in the technical menu being modified without
authorisation.
5.1.3. HOT WATER TEMPERATURE
The water temperature is shown on the display .
NOTE
: The circulating pump activation temperature is a factory setting.
In the event of excess water temperature the device warns the user with an indicator light and an audible signal; the latter may be enabled
or disabled via the BUZZER function in the MENU.
See EXCESS TEMPERATURE ALARM.
5.1.4. FROST PROTECTION
The frost protection function is always active on the device and acts by starting the pump when the temperature measured by the probe is
less than 5°C / 41°F (fixed threshold).
When the frost protection function is active, LED 1 Danger comes on and the message “FROST PROTECTION” is shown on the display.