![LA NORDICA TermoRosa Ready D.S.A Instructions For Installation, Use And Maintenance Manual Download Page 21](http://html2.mh-extra.com/html/la-nordica/termorosa-ready-d-s-a/termorosa-ready-d-s-a_instructions-for-installation-use-and-maintenance-manual_3118166021.webp)
21
1. TECHNICAL DATA
Definition
: in accordance with
EN 12815
Constructive
system
Global
thermal
power
in kW
Nominal
thermal
power
in kW
Power
given back
to water
in kW
Power
given back
to the room
in kW
Hourly wood consumption
in kg / h (wood with 20% humidity)
Efficiency
in %
CO
measured at 13% oxygen in %
Smoke outlet
diameter in mm
Chimney
height - dimension in mm (
#
)
Fluid contents of the exchanger
in L (litres)
Chimney draught
in
Pa
(mm H
2
O)
Boiler connections
(Ø)
Automatic discharge pipe
diameter (Ø)
Outer air inlet
in cm
2
Exhaust gas emission
in g/s – wood
Exhaust gas temperature
in °C - wood
Optimal working temperature
in °C
Max. working pressure
in bar (expansion vessel
Open
-
Closed
)
Hearth opening size
in mm (W x H)
Hearth size
in mm (W x H x D)
Oven
size
in mm (W x H x D)
Type of grill
Movable - flat
Height
in mm
Width
in mm
Depth
in mm
Weight
in Kg
Fire prevention safety distances
Chapter
SAFETY
heatable m
3
(30 kcal/h x m
3
) (
# #
)
(
#
) 200 mm diameter can be used with flue of no less than 6 m.
(
# #
)
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume
of the product is: favourable type of building (30 Kcal/h x m
3
); less favourable type of building (40 Kcal/h x m
3
); unfavourable type of
building (50 Kcal/h x m
3
).
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating,
in the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
IMPORTANT
: The power of the connected heating system must be proportional to the power transferred to the water by the thermoproduct;
a charge which is too low does not allow regular oven operation, while a charge which is too high prevents adequate radiator heating.
2. GENERAL PRECAUTIONS
La NORDICA S.p.A. responsibility is limited to the supply of the appliance.
The installation must be carried out scrupulously according to the instructions provided in this manual and the rules of the profession.
Installation must only be carried out by a qualified technician who works on behalf of companies suitable to assume the entire responsibility
of the system as a whole.
La NORDICA S.p.A. declines any responsibility for the product that has been modified without written authorisation as well as
for the use of non-original spare parts. NO MODIFICATIONS CAN BE CARRIED OUT TO THE APPLIANCE. La NORDICA S.p.A.
cannot be held responsible for lack of respect for such precautions.
This appliance is not suitable for the use of inexperienced people (included children) or with physical, sensorial and mental reduced
capacities. They have to be controlled and educated in the use of the appliance from a responsible person for their security. The children
have to be controlled to be sure that they would not play with the appliance. (EN 60335-2-102/7.12).
It is OBLIGATORY to respect the National and European rules, local regulations concerning building matter and also fireproof
rules.
3. INSTALLATION REGULATIONS
Installation of the product and auxiliary equipment in relation to the heating system must comply with all current Standards and Regulations
TERMOROSA READY - DSA
1
19.4
15.5
9
6.5
4.5
79.9
0.12
150 S/P
5m – 220x220 Ø220
14
17 - 20 (1.7 - 2.0)
1 ”F gas
½”M gas
200 (100 cm
2
)
15.5
241
70-75
VEA 1,5 bar - VEC 3 bar
220 x 265
265 x 285 x 400
330 x 300 x 410
893
1027
761
230
444