background image

 

 

Alarm 
time 

Weather 

tendency 

indicator

Time Display

 

Calendar display 

Indoor 
relative 
humidity 
in RH%

 

Alarm 
icon

Indoor 
temperature 
in ºF/ ºC

 

Weather 
forecast 
icon

 

Outdoor 
data signal 
reception 
indicator

Outdoor 
temperature 
in ºF/ ºC

 

Outdoor 
transmitter 
identification 
number 

Outdoor 
relative 
humidity 
in RH%

WWVB Signal 
Reception Icon

LCD SCREEN  

The LCD screen is split into 5 sections displaying the information for time, date, weather forecast, indoor 
data, and outdoor data.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
MANUAL SETTINGS: 

The following manual settings can be changed after entering the manual set-up mode: 

 

LCD contrast setting 

 

Time zone setting 

 

DST (Daylight Saving Time) setting 

 

Time reception ON/OFF setting 

 12/24-Hour 

setting 

 

Manual time setting 

 Calendar 

setting 

 Snooze 

setting 

 °F/°C 

setting 

 

Weather forecasting icon sensitivity setting 

 

LCD CONTRAST SETTING: 

 
 
 

 

The LCD contrast can be set within 8 levels, from LCD 0 to LCD7 (Default setting is LCD 5): 
1. 

Press and hold the SET key until the digit starts flashing. 

2. 

Use the CH/+ key to view all levels of contrast.  

3. 

Select the desired LCD contrast. Confirm with the SET key and enter in the 

Time Zone setting

 

TIME ZONE SETTING: 

 

 
 

Alarm icon

 

Indoor relative 
humidity in RH%

 

DCF reception icon 
(for DCF time) 

Last digit flashing

Number 
Digit 
Flashing 

Summary of Contents for WS-9520U

Page 1: ...calendar moon phase indoor and outdoor temperature indoor and outdoor relative humidity this unit will never keep you guessing on current and future weather conditions Operation of this product is sim...

Page 2: ...n orientation possible LCD contrast selectable E L back light Low battery indicator Table standing AC DC power adapter included The Remote Temperature Humidity Sensor Remote transmission of outdoor te...

Page 3: ...data is displayed proceed to step 2 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To install and replace batterie...

Page 4: ...ries and wait for at least 3 minutes before reinserting them 2 Within 4 minutes of activating the weather projection station place the batteries into the remote temperature humidity sensor see To inst...

Page 5: ...humidity sensor need to be reset when one of the following conditions occur Unsuccessful 433MHz signal reception Malfunction of the units Batteries need replacement For resetting remove all batteries...

Page 6: ...me announced at the top of the minute in Coordinated Universal Time which is also known as Greenwich Mean Time GMT This time does not follow Daylight Saving Time changes After the top of the minute a...

Page 7: ...on HOUR IN key Press to set the alarm hour inside alarm setting mode Press shortly to toggle between MIN MAX and current indoor temperature and humidity data Press and hold for 4 seconds to reset the...

Page 8: ...er identification number Outdoor relative humidity in RH WWVB Signal Reception Icon LCD SCREEN The LCD screen is split into 5 sections displaying the information for time date weather forecast indoor...

Page 9: ...be adjusted according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF 1 The digit ON will start flashing on th...

Page 10: ...set time into the received time During reception attempts the WWVB tower icon will flash If reception has been unsuccessful then the WWVB tower icon will not appear but reception will still be attempt...

Page 11: ...ations with rapid changes of weather conditions the weather icons can be set to a different level for faster display of weather conditions 1 The current sensitivity value will start flashing 2 Use the...

Page 12: ...in the air pressure the weather icons will update accordingly to represent the change in weather If the icons do not change then it means either the air pressure has not changed or the change has bee...

Page 13: ...te Once the weather tendency indicator has registered a change in air pressure it will remain permanently visualized on the LCD WEATHER BOY FORECASTING ICONS A total of 24 Weather Boy icons combinatio...

Page 14: ...3 Three times to return to transmitter 1 Note The transmitter number will only be displayed if there is more than one transmitter being used 3 To reset the MIN MAX outdoor temperature and the time at...

Page 15: ...ment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up above POSITIONING THE REMOTE TEMPERATURE HUMIDITY SEN...

Page 16: ...0 2 x 169 6 x 74 4 mm Remote temperature humidity sensor 6 29 x 1 69 x 0 90 inches 160 x 43 x 23 mm LIABILITY DISCLAIMER The manufacturer and supplier cannot accept any responsibility for any incorrec...

Page 17: ...warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresen...

Page 18: ...ICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED INC...